Problem
Probable cause(s)
One or more
No power to the fixture.
fixtures are
completely dead.
Primary fuse blown.
Fixtures reset
The controller is not connected.
correctly, but all
3-pin XLR Out of the controller does
respond erratically
not match XLR Out of the first fixture
or not at all to the
on the link (i.e. signal is reversed).
controller.
Poor data quality
Bad data link connection
Fixtures reset
correctly, but some
Data link not terminated with 120
Ohm termination plug.
respond erratically
or not at all to the
Incorrect addressing of the fixtures.
controller.
One of the fixtures is defective and
disturbs data transmission on the
link.
3-pin XLR Out on the fixtures does
not match (pins 2 and 3 reversed).
Shutter closes
The color wheel, gobowheel or a
suddenly
gobo has lost its index position and
the fixture is resetting the effect.
Fixture is too hot.
No light or lamp
cuts out
LEDs damaged
intermittently
The power supply settings do not
match local AC voltage and
frequency.
Ordercode: 41531
Remedy
Check that power is switched on and
cables are plugged in.
Replace fuse.
Connect controller.
Install a phase reversing cable between
the controller and the first fixture on the
link.
Check data quality. If much lower than
100 percent, the problem may be a
bad data link connection, poor quality
or broken cables, missing termination
plug, or a defective fixture disturbing
the link.
Inspect connections and cables.
Correct poor connections. Repair or
replace damaged cables.
Insert termination plug in output jack of
the last fixture on the link.
Check address setting.
Bypass one fixture at a time until normal
operation is regained: unplug both
connectors and connect them directly
together.
Have the defective fixture serviced by a
qualified technician.
Install a phase-reversing cable between
the fixtures or swap pin 2 and 3 in the
fixture, that behaves erratically.
Contact a technician for servicing the
problem persists.
Allow fixture to cool.
Clean fan.
Make sure air vents at control panel
and front lens are not blocked.
Turn up the air conditioning .
Disconnect fixture and return to your
dealer.
Disconnect fixture. Check settings and
correct if necessary.