8.5 Altitude

Operating -
Storage -
Shipping -

8.6 Air pressure

Operating -
Storage -
Shipping -
8.7

Environmental test

Cold test (-25 degree,96 hours)
Damp heat steady state (40 degree, 95% RH, 96 hours)
Dry heat test (70 degree, 96 hours)

9. REGULATORY COMPLIANCE

9.1

Worldwide Regulatory

REGION
COUNTRY
DOMAIN
(RSO)
(NSO)
World
World wide
wide
Europe
EUROPE
AP
General Product Specification
SAFETY / EMC / ERGONOMICS /
STANDARDS
IEC60950-1:2001 (EN60950-
1:2001+A11:2004). Group and
national differences of all countries
listed in CB Bulletin No. 107A
Sa
or
IEC60950-1:2005 (EN60950-1:2006)
and National difference of all
countries
European Low Voltage Directives
Sa
2006/95/EC
European Electromagnetic
Compatibility Directive 2004/108/EC
EN55022:2006+A1:2007
EN55024:1998+A1:2001+A2:2003,
EN61000-3-2:2006,
E
EN61000-3-
3:1995+A1:2001+A2:2005
EN 55013:2001+A1:2003+A2:2006
(for A/V)
EN 55020:2007
EUP Directive 2005/32/EC (EC No.
1275/2008 implementing)
O
Energy Saving
IEC62087 + IEC62301
0 to 4500m
0 to 9000m
0 to 9000m
795 to 1013 mbar
300 to 1013 mbar
300 to 1013 mbar
DOCUMENTS
CB Report, certificate
Declaration of Conformity
EMC/CE test report
EUP