Positioning, Assembly And Installation; Environment Of Use; Examples Of Installation - Ravelli AURORA CANALIZZATA User And Maintenance Manual

Table of Contents

Advertisement

Available languages

Available languages

3
mm mm mm Kg mm m
AURORA
1177 520 520 155
80
300
CANAL.
AURORA
1191 520 520 150
80
300
VENTIL.
CAMILLA
1189 525 510 141
80
240
EVA
1068 500 545 134
80
240
VISION
FLAVIA
1003 513 488
92
80
220
HOLLY C.
1073 500 542 140
80
300
/RC120
HOLLY V.
1073 500 542 140
80
300
/RV120
LISA
960 450 480 90
80 150
PLUS
MAVÌ
1080 575 590 85
80 150
MILENA
1100 550 540 140 80 230
MONICA
1003 513 457
92
80
205
OLIVIA
1130 800 250 100 80 170
R70
951 440 450
92
80
150
RC70
951 440 491.5 95
80
210
RV80
986 512 484
90
80
195
RV100
1099 524 532 130
80
240
RV110
1115 552 606 145
80
265
R1000
790 587 446
97
80
240
RC1000
627 753 591 106
80
230
SNELLA
1158 817 364 140
80
270
SOFIA
949 635 585 196
80
300
SPILLO
770 710 650 220
80
320
The data shown above are indicative and not binding. Ravelli reserves the right to make
any modifications for the purpose of improving the performances of the product. For
any information related to the dimention and weigth of the stove, please refer to the
dedicated leaflet.
Pag.18
Kw/h
Kg/h
h
%
%
V
min
min
W
-
Kg
min
min
min
-
-
Hz
-
-
-
max
max
max
max
max
2.5
0.7
230
8.5
89
0.013
-
-
110
-
22
-
-
-
12.5
2.6
50
31.5
85
0.028
2.5
0.75
230
5.3
90
0.014
-
-
280
-
15
-
-
-
12.5
2.8
50
20
86.5
0.028
2.8
0.6
230
9.5
87.5
0.012
-
-
110
-
23
-
-
-
10
2.2
50
38
91
0.029
2.8
0.6
230
6
87.5
0.012
-
-
110
-
15
-
-
-
10
2.2
50
25
91
0.029
2.8
0.5
230
8.3
0.020
>
-
-
110
-
13
-
-
87.5
9
1.8
50
30
0.040
3.3
0.75
230
9.6
85
0.013
-
-
110
-
25
-
-
-
11.83
2.64
50
41
89.4
0.028
2.9
0.66
231
8.4
86.9
0.014
-
-
120
-
25
-
-
-
11.92
2.8
50
42
90.5
0.028
3.3
0.5
230
9.3
0.015
-
-
100
-
15
-
>90
-
7
1.6
50
30
0.020
2.9
0.65
230
9.3
0.017
-
-
100
-
15
-
89
-
5.5
1.31
50
30
0.019
2.5
0.5
230
12.4
0.03
-
-
110
-
31
-
87
-
12
2.5
50
62
0.04
2.8
1.8
230
8.3
0.020
-
-
110
-
15
-
>85
-
8.5
0.5
50
30
0.040
3.3
0.72
230
12
0.031
-
-
110
-
20
-
92
-
7.1
1.67
50
28
0.023
2.5
0.5
230
9.3
0.019
-
-
100
-
15
-
>85
-
7.5
1.6
50
30
0.040
2.5
0.5
230
8
87.5
0.020
-
-
340
-
13
-
-
-
8
1.7
50
26
87.5
0.040
2.99
0.68
230
9
81.85
0.014
-
-
110
-
15
-
-
-
8.02
2
50
21
89.60
0.032
2.8
2.2
230
10.5
87.5
0.012
-
-
110
-
25
-
-
-
10
0.6
50
42
91
0.029
3.1
0.7
230
10
93
0.017
-
-
280
-
22
-
-
-
10.5
2.2
50
31.5
88
0.027
2.5
0.5
230
4.5
0.022
-
-
110
-
13
-
>87
-
10
2.1
50
18
0.028
3
0.6
230
6.3
0.016
-
-
110
-
15
-
>87
-
9.5
2
50
25
0.017
3.5
0.7
230
12
0.015
-
-
110
-
30
-
>85
-
11
2.5
50
43
0.053
3.3
2.6
230
7
0.015
-
-
110
-
20
-
>86
-
12
0.7
50
30
0.017
3.5
2.6
230
7
0.015
-
-
110
-
20
-
>86
-
12.5
0.7
50
30
0.016

6. POSITIONING, ASSEMBLY AND INSTALLATION

6.1 Environment of use

The positioning of the stove is decisive for successful even heating of the
room. Before deciding where to place the stove, the following must be taken
into account:
• the stove must be installed on a floor with a sufficient carrying capacity. If
the existing building does not meet this requisite, appropriate measures
must be taken (i.e. load distribution plate).
• the combustion air cannot be obtained from a garage or from an area with-
out ventilation or exchange of air, but from a free or external space
g/s
°C
• the stove must not be installed in a bedroom, bathroom or shower, or where
mbar
min
-
min
-
Pa
-
there is already another heating appliance without an autonomous air flow
max
max
(chimney, stove etc.)
• in the case of a wood floor, prepare the floor-protection pedestal (glass plate or
4.81
0.1
121
steel)
-
-
-
8.60
10
281
• installation is better in a large and central room in the house to ensure
maximum circulation of the heat;
4.57
0.1
114
• connection to the mains supply is recommended using an earth socket (if
-
-
-
8.40
10
265
the cable supplied is not long enough to reach the nearest socket, use an
extension flush with the ground);
3.8
0.1
83
• the stove must be placed in a position that receives the necessary level of air
-
-
-
7.4
10
189
for appropriate combustion of the pellets (at least 40 m
in accordance with installation regulation and local legislations;
3.8
0.1
83
• the minimum volume of the installation area must be 30 m
-
-
-
7.4
10
189
• The installer of the stove should guarantee an installation with easy access
to the stove and of the chimney
0.29
0.1
153
-
-
-
0.81
10
195
The stove must be installed and assembled by qualified personnel.
The room must be:
4.81
0.1
121
• prepared for the environmental functioning conditions
-
-
-
• prepared with an adequate system of evacuation of smoke
8.60
10
281
• have a 230V 50 Hz (EN73-23) electricity mains supply
• have external ventilation (minimum section 100 cm
4.57
0.1
114
-
-
-
• have a CE compliant earthing system
8.40
10
265
• The stove must be connected to a SINGLE flue or – internal or exter-
4.24
0.1
113
-
-
-
nal - vertical pipe in compliance with the regulations in force.
5.14
10
188
• The smoke is the result of the combustion of wood therefore if it
comes into contact with the walls it may dirty them.
3.37
0.1
121
-
-
-
• It is not compulsory to connect the air intake of the stove directly
4.93
10
171
with the outside but at least 50m3/h of air must be guaranteed.
• The use of a mesh at the end of the exhaust pipe is absolutely forbid-
9.4
0.1
103
-
-
-
den as this could cause the poor functioning of the stove.
11.3
10
209
• Tubes and joints with adequate silicone gaskets must always be used
to guarantee the seal of the smoke pipes.
0.29
0.1
153
-
-
-
• For the connection to the flue, no more than 3 90° bends must be
0.81
10
195
used and they must not be used more than 2-3 metres in horizontal.
• IMPORTANT!!!! If the installation of the product is supposed to be
4.19
0.1
97
-
-
-
next to flammable wall, the minimum distance, indicated on the la-
7.77
10
174
bel located on the back of the stove, must be respect. In case the
product is installed next to unflammable walls no specific distances
0.29
0.1
153
are required.
-
-
-
0.76
10
185
• The installation can not be done in a shared flue.
0.29
0.1
153

6.2. Examples of installation

-
-
-
0.76
10
185
3.42
0.1
120
-
-
-
7.74
10
226
3.8
0.1
83
-
-
-
7.4
10
189
3.8
0.1
83
Protection from rain
-
-
-
7.4
10
189
4.6
0.1
130
YES
-
-
-
8.31
10
219
9.3
0.1
119
-
-
-
9.4
10
211
5.3
0.1
63
-
-
-
10
10
124
6
0.1
118
-
-
-
9.6
10
196
6
0.1
118
-
-
-
9.5
10
195
This type of installation (see Fig. 9) requires an insulated flue, as all the
smoke pipe has been installed outside the house.
3
/h must be available),
3
.
)
2
Fig.9
Insulated fl ue
Fig.11
Union tee for condensation

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents