4. Safety devices

The stove is fitted with sophisticated safety systems so that, in the case of breakage of one of the individual parts or defects in the flue,
no damage will be caused to the stove and the room in which it is installed. In any case, when a problem arises, the pellets stop falling
immediately and the " switch off " phase is activated.
The corresponding alarm will be shown on the display. The details can be seen in chapter 9 "DESCRIPTION OF ALARMS".

5. TECHNICAL FEATURES

Height
Width
Depth
Weight
Diameter of smoke
exit tube
Min-max. hourly
consumption of pellets
Supply
Hopper capacity
Efficiency *
Smoke temperature
min - max
*overll heating efficency is determined using higher heating value of the fuel.
The data shown above are indicative and not binding. Ravelli reserves the right to make any
modifications for the purpose of improving the performances of the product.

6. Positioning, assembly and installation

6.1 Minimum distance from combustible material

A
Unit of measure-
ment
Inch/mm
R =right side
L = left side
Inch/mm
Inch/mm
B = rear side
Inch/mm
A = front side
Inch/mm
D = FRONT floor
protection
E = SIDE floor
Inch/mm
protection
F = Ceiling
Inch/mm
N.B. The floor protection must extrend under the chymney connector and 2 inches (50.8mm) beyond each side
User and maintenance manual for stoves with RDS technology
Unit of
Francesca
measurement
2015
Inch
37.67
Inch
17.32
Inch
18.46
Lbs
200
Inch
3.14
Lbs/h
1.1 - 3.5
V - Hz
120 - 60
Lbs
35
%
77.9
°F
176 - 302
L
B
R
Francesca
2015
4 / 101,6
4 / 101,6
2 / 50,8
39,37 /
39,37 / 1000
1000
6 / 152,4
6 / 152,4
57 / 1450
RV 80
Monica
Ceramica
2015
39
39.3
20.20
20.27
19.1
18.58
270
264
3.14
3.14
1.1 - 3.5
1.1 - 3.5
120 - 60
120 - 60
35
35
77.9
77.9
176 - 302
176 - 302
NOTE: Install vent at clearances specified by the
vent manufactures.
E
RV 80
Monica
Ceramica
2015
4 / 101,6
4 / 101,6
4 / 101,6
4 / 101,6
2 / 50,8
2 / 50,8
39,37 / 1000
6 / 152,4
6 / 152,4
6 / 152,4
6 / 152,4
57 / 1450
57 / 1450
RV 100
Roma
Classic
44.1
31.5
21.7
43.4
21.9
29.5
320
550
3.14
3.14
1.5 - 5.1
1.6-5
120 - 60
120-60
50
50
80.2
75.5
200 - 415
240-410
E
D
RV 100
Spillo
Classic
4 / 101,6
7,87 / 200
4 / 101,6
7,87 / 200
4 / 101,6
7,87 / 200
39,37 / 1000
39,37 / 1000
6 / 152,4
6 / 152,4
6 / 152,4
6 / 152,4
52 / 1321
--
01/02/2016
Pag.10
SPILLO
RV 100
30.30
42.5
28
20.87
25.6
21.25
451
264-242
3.14
3.14
1.8-6.6
1.1-5.0
120-60
120-60
44
44
85
84
158-195
217-408
RV 100
11,81 / 300
11,81 / 300
7,87 / 200
39,37 / 1000
6 / 152,4
6 / 152,4
--