Specifications (Cont.) PT‐14W PT‐25W PT‐24‐8W PT‐24‐13W
Output Banks:
Battery Capacity (Amp‐Hours):
Weight (Lbs./Kg.):
Compliance References:
Compliance References*:
CG
Ignition protected per USCG CFR 183.410
CE
Carries the CE Mark
* Numerous other Safety and EMC compliances may also apply. Contact factory if further
compliance information is required.
Temperature Rating (all models):
‐10°C to +60°C; Derate linearly from 100% @ 50°C to 60% @ 60°C
Nominal Output Voltages at Gel/Flooded Switch Settings (without Temperature Compensation
option installed or at 22.2°C (72°F) with Temperature Compensation option installed):
Charge
Setting @ 50 % load @ .5 amp load
Gel‐Cell
14.0V DC
Flooded/AGM 14.2V DC
Temperature Compensation: ‐ 5 mV per cell per ° C. Sensor supplied with 25' cable and plug‐in
connector
Remote Panel, Model RP: LED's indicate charger output stage. Button allows manual
reinitialization of three stage charge cycle. Supplied with 25' cable and plug‐in connector. Panel
dimensions: 3" H x 4.75" W
Protection (all models): Input/Output Fuses, Current Limiting, Thermal Protection, Forced Air
Cooling, Drip Shield
Case Size: 11.10" H* x 7.75" W x 4.75" D*
* Add 1.15" (2.92 cm) to height and .95" (2.41 cm) to depth for drip shield
VII
TROUBLESHOOTING
Note: These chargers incorporate self‐contained AC to DC conversion modules which utilize numerous
automatic protection circuits. The AC input fuse which protects internal wiring is housed inside the
charger with the module. Under most circumstances the fuse will fail only if the charger has an internal
fault. Hence, they are not intended to be user‐replaceable and any condition which has caused a blown
AC fuse will likely require repair of other internal circuitry by a qualified technician. If an apparent
3
28‐140
50‐250
7.5
CG, CE CG
12 Volt Models
Float
13.6V DC
13.4V DC
3 3 3
16‐80
8.5
7.5
CG, CE
24 Volt Models
Charge
Float
@ 50 % load @ .5 amp load
28.0V DC
27.2V DC
28.4V DC
26.8V DC
26‐130
8.5
CG