G) Gel-Cell/Lead Acid Selector
Checking or Setting the Selector
The ideal charge/float regimen has been programmed into the
Phase Three Charger for either sealed gel-cell or flooded lead-acid
batteries depending on the selector position. The selector has been
factory set in the lead-acid position. In order to check or change
the gel/lead-acid selector setting, proceed as follows (see Figures
5 & 6):
1) Ensure A.C. power to the charger is shut off.
2) Locate the access plate on top of the charger and loosen the two
Phillips head screws (DO NOT REMOVE SCREWS.) Remove access
plate.
3) Locate the gray circular switch which is recessed into the
internal black module. (Note: There may be a self-adhesive black
�����������������
�������������������������
9
P.O. Box 1306, Newport Beach, California 92663 • Phone: 714-751-0488 • Fax: 714-957-1621 • E-Mail: techservice@newmarpower.com
����������������������������
FIGURE 5: Gell-Cell/Lead Acid Selector
��������������
FIGURE 6: Gel-Cell/Lead-Acid Selector Positions
������������
plastic cover over this switch, remove cover.) This switch has 16
selector positions: 0,1,2,3,4,5,6,7,8,A,B,C,D,E,F. Positions 0 thru 7
correspond to Flooded/Lead Acid, positions 8 thru F correspond to
Gell-Cell/VRLA
4) Use a flat blade screwdriver to rotate the switch into the correct
position, with either "F" or "7" showing as illustrated below:
5) If installing the optional Temperature Compensation Sensor,
proceed with that installation (described in section H following).
6) Reinstall the access plate and tighten the two Phillips head
screws.
�������������������
����������������
���������������
��
����������������