Maintaining And Servicing Your Fireplace - Heat-N-Glo Pier-PV-IPI Installer's Manual

Table of Contents

Advertisement

4

Maintaining and Servicing Your Fireplace

Fireplace Maintenance
Although the frequency of your fireplace servicing and main-
tenance will depend on use and the type of installation, you
should have a qualified service technician perform an ap-
pliance check-up at the beginning of each heating season.
See the table below for specific guidelines regarding each
fireplace maintenance task.
IMPORTANT: TURN OFF THE GAS BEFORE SERVIC-
ING YOUR FIREPLACE.
Replacing old ember material
Frequency: Once annually, during the checkup.
By: Qualified service technician.
Task: Brush away loose ember material near the burner.
Replace old ember material with new dime-size and shape
pieces of Golden Ember (GE-93) and Glowing Ember (050-
721). New ember material should be placed alternately on
top of the burner - a layer of Golden Ember, a layer of
Glowing Ember, and so on. Save the remaining ember
material and repeat this procedure at your next servicing.
For more information, see Placing Ember Material.
Cleaning Burner and Controls
Frequency: Once annually.
By: Qualified service technician.
Task: Brush or vacuum the control compartment, fireplace
logs and burner areas surrounding the logs.
Cleaning Flame Sensor Rod (IPI Systems)
Frequency: Periodically.
By: Qualified service technician.
Task: Make a visual check of the straight flame sensor
rod. Use emery cloth to carefully remove any existing film
or white deposits.
Checking Flame Patterns, Flame Height
Frequency: Periodically.
By: Qualified service technician/Home owner.
Task: Make a visual check of your fireplace's flame
patterns. Make sure the flames are steady - not lifting or
floating. See Figure 37. The flame sensor (IPI) or
thermopile/thermocouple (standing pilot) tips should be
covered with flame. See Figure 23.
MAKE SURE THE FLAMES
ARE STEADY—NOT
LIFTING OR FLOATING.
Figure 37. Burner Flame Patterns
Checking Vent System
Frequency: Before initial use and at least annually
thereafter, more frequently if possible.
By: Qualified service technician/Home owner.
Task: Inspect the external vent cap on a regular basis to
ensure that no debris is interfering with the flow of air.
Inspect entire vent system for proper function.
Cleaning Glass Door
Frequency: After the first 3 to 4 hours of use. As neces-
sary after initial cleaning.
By: Home owner.
Task: Remove and clean glass after the first 3 to 4 hours
of use. After the initial cleaning, clean as necessary, par-
ticularly after adding new ember (flame colorant) material.
Film deposits on the inside of the glass door should be
cleaned off using a household glass cleaner. NOTE: DO
NOT handle or attempt to clean the door when it is hot
and DO NOT use abrasive cleaners.