Step 3. Installing the Vent System

A. Vent System Approvals
These models are approved to use PVFLEX series vent
pipe components and terminations (see Figure 5). Ap-
proved vent system components are labeled for identifi-
cation. This pipe is tested and listed as an approved com-
ponent of the fireplace. The pipe is tested to be run inside
an enclosed wall. There is no requirement for inspection
openings at each joint within the wall. There is no required
pitch for horizontal vent runs. NO OTHER VENTING SYS-
TEMS OR COMPONENTS MAY BE USED.
TERMINATION KITS
PV-HORZ
LISTED VERTICAL
B-TYPE TERMINATION
STORM
COLLAR
ROOF
FLASHING
LISTED
SINGLE WALL
B-VENT
PV-VERT
PV-HORZ
INSIDE WALL OR
CEILING FIRESTOP
Figure 5.
Vent System Components and Termination Kits
PV-VERT
PV-FS
FIRESTOP
90 DEGREE
BEND
Detailed installation instructions are included with each vent
termination kit and should be used in conjunction with this
Installers Guide.
The flame and ember appearance may vary based on the
type of fuel burned and the venting configuration used.
PV-WIRE
PVWIRE-10 .....10 feet, 5 wire harness
PVWIRE-40 .....40 feet, 5 wire harness
PVWIRE-80 .....80 feet, 5 wire harness
PV-FLEX-10
10' Length of Flex Pipe
25' Length of Flex Pipe
PV-FLEX-25
PVFLEX-CONNECT