C-Control Panel; D-Notes To The User; E-Enter The Customer Access Code - Traulsen R & ASeries Owner's Manual

Table of Contents

Advertisement

VII. c - CONTROL PANEL:
LED FOR °
F
INTELA-TRAUL
°F
3-DIGIT (RED)
LED DISPLAY
SET
ALARM CANCEL
BUTTON
DEFROST ICON
FREEZER
W / LED
VII. d - NOTES TO THE USER:
You only have 20-30 seconds between button pushes. If you take longer than 30 seconds, the controller will revert back to
displaying the cabinet temperature. If you enter the wrong security code, the controller will revert back to displaying the cab-
inet temperature. You can exit the parameters at any time by pressing the alarm cancel button or by waiting 20-30 seconds.
VII. e - ENTER THE CUSTOMER ACCESS: This is required to set any of the control parameters
Use the security code 0, A, 1
Press the set button
Press the set button
The display will show three zeros with the left zero flashing
Press the set button
The display will show three zeros with the center zero flashing
Press the down arrow key
When you reach A press set
The display will show zero, A, zero with the right zero flashing
Press the up arrow key
When you reach 1 press set
The display will read
You are now in the CUSTOMER / SERVICE PARAMETERS.
VII. INTELA-TRAUL
DOOR OPEN ICON
W / LED
)
)
)
and the following instructions:
.
The display will read
SET
.
SET
.
SET
to sequence through F, E, d, C, b, A, 9, 8, 7,...etc.
SET
.
to sequence through 1, 2, 3, 4, 5, 6, 7, 8, 9, A, b,...etc.
.
SET
Thermostat Set Point. Press
(continued)
®
Customer/Service Access.
.
to view and
SET
-10-
.
.
again to exit.
SET