KEPCO KLP 10-150 Quick Start Manual
Hide thumbs Also See for KLP 10-150:

Advertisement

Quick Links

Q U I C K S T A R T G U I D E
KEPCO
This guide gives a brief introduction to the KLP Power supply, shows simple load connections, and
allows you to verify the power supply is working. The guide also shows you how to use the front panel
controls to perform the most commonly used functions.
Accessing Manuals. First determine your Firmware Version (see below), then download the KLP User
Manual and Developer's Guide from www.kepcopower.com/support/opmanls.htm#klp. Refer to the KLP
User Manual for full specifications, installation considerations and operating instructions. An Installation/
Operation Summary includes hyperlinked references to detailed procedure, but which can be printed as
a handy reference. Refer to the KLP Developer's Guide for a full description of the digital interfaces, their
associated drivers, and the SCPI command language.
Firmware Version. Refer to www.kepcopower.com/utility/util.htm to determine which firmware version is
installed. The KLP can be upgraded to the latest version at no cost using the Kepco Upgrade Utility, also
available at www.kepcopower.com/utility/util.htm.
Accessing Drivers. Drivers are accessed from www.kepcopower.com/drivers/drivers-dl3.htm.
DESCRIPTION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
UNPACKING. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
EQUIPMENT SUPPLIED. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
ACCESSORIES. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
SAFETY. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
PRELIMINARY OPERATIONAL CHECK. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
INSTALLATION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Input Connections. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Load Connections. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Local Sensing (Factory Default). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Remote Sensing Select. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Analog I/O Connections. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
GPIB Connections. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
RS 232 Connections (Standard Models). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
LAN Connections (E-Series Models). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
OPERATION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Turning the Power Supply On. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Enabling/disabling Output Power. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Checking or changing Voltage/Current Setpoints. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Virtual Model Setting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Setting voltage or current. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Last Setting Recall. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Viewing/Changing Overvoltage or Overcurrent Protection Values. . . . . . . . . . . . . . . . . . . . . . . . . 10
KLP OUTLINE DIMENSIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
KEPCO, INC. " 131-38 SANFORD AVENUE " FLUSHING, NY. 11355 U.S.A. " TEL (718) 461-7000 " FAX (718) 767-1102
©2013, KEPCO, INC
Data subject to change without notice
An ISO 9001 Company.
KLP POWER SUPPLY
CONTENTS
228-1616 REV 7
KLP
070113

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the KLP 10-150 and is the answer not in the manual?

Questions and answers

Summary of Contents for KEPCO KLP 10-150

  • Page 1: Table Of Contents

    SCPI command language. Firmware Version. Refer to www.kepcopower.com/utility/util.htm to determine which firmware version is installed. The KLP can be upgraded to the latest version at no cost using the Kepco Upgrade Utility, also available at www.kepcopower.com/utility/util.htm.
  • Page 2: Description

    * User Manual and Developer’s Guide are available as free downloads from: www.kepcopower.com/support/opmanls.htm#klp Drivers are available as free downloads from www.kepcopower.com/drivers/drivers-dl3.htm#klp KEPCO, INC. " 131-38 SANFORD AVENUE " FLUSHING, NY. 11355 U.S.A. " TEL (718) 461-7000 " FAX (718) 767-1102 http://www.kepcopower.com " email: hq@kepcopower.com 228-1616 REV 7 070113...
  • Page 3: Accessories

    INDICATES THE POSSIBILITY OF BODILY INJURY OR DEATH. CAUTION INDICATES THE POSSIBILITY OF EQUIPMENT DAMAGE. KEPCO, INC. " 131-38 SANFORD AVENUE " FLUSHING, NY. 11355 U.S.A. " TEL (718) 461-7000 " FAX (718) 767-1102 http://www.kepcopower.com " email: hq@kepcopower.com 070113 228-1616 REV 7...
  • Page 4: Preliminary Operational Check

    12 Set POWER ON/OFF circuit breaker to OFF and disconnect from source power, load and test equip- ment. KEPCO, INC. " 131-38 SANFORD AVENUE " FLUSHING, NY. 11355 U.S.A. " TEL (718) 461-7000 " FAX (718) 767-1102 http://www.kepcopower.com " email: hq@kepcopower.com...
  • Page 5: Installation

    NOTE: Output Sense lines must be connected for proper operation, either locally, or at the load (remote). FIGURE 1. KLP SERIES, FRONT PANEL CONTROLS AND INDICATORS KEPCO, INC. " 131-38 SANFORD AVENUE " FLUSHING, NY. 11355 U.S.A. " TEL (718) 461-7000 " FAX (718) 767-1102 http://www.kepcopower.com " email: hq@kepcopower.com 070113...
  • Page 6: Local Sensing (Factory Default)

    Figure 3 is recommended to reduce noise in the sense loop. FIGURE 3. REMOTE SENSING KEPCO, INC. " 131-38 SANFORD AVENUE " FLUSHING, NY. 11355 U.S.A. " TEL (718) 461-7000 " FAX (718) 767-1102 http://www.kepcopower.com " email: hq@kepcopower.com...
  • Page 7: Analog I/O Connections

    • Since the output is off, Constant Voltage (CV) mode indicator (green LED) and Constant Current (CC) indicator (amber LED) are off. KEPCO, INC. " 131-38 SANFORD AVENUE " FLUSHING, NY. 11355 U.S.A. " TEL (718) 461-7000 " FAX (718) 767-1102 http://www.kepcopower.com " email: hq@kepcopower.com...
  • Page 8: Enabling/Disabling Output Power

    To exit, rotate either VOLTAGE or CURRENT control until Status display reads EXIT, then tap DC OUTPUT switch. To change the virtual model limits refer to the User Manual. KEPCO, INC. " 131-38 SANFORD AVENUE " FLUSHING, NY. 11355 U.S.A. " TEL (718) 461-7000 " FAX (718) 767-1102 http://www.kepcopower.com " email: hq@kepcopower.com...
  • Page 9: Setting Voltage Or Current

    • If you decide not to change the value after rotating the control, the previous setpoint value will be restored after about 20 seconds of inactivity. Then tap either adjustment control to accept. KEPCO, INC. " 131-38 SANFORD AVENUE " FLUSHING, NY. 11355 U.S.A. " TEL (718) 461-7000 " FAX (718) 767-1102 http://www.kepcopower.com " email: hq@kepcopower.com...
  • Page 10: Last Setting Recall

    When the PROTECT switch is released, the protection values showing in the DC VOLTS and DC AMPERES displays are entered as the new protection values. KEPCO, INC. " 131-38 SANFORD AVENUE " FLUSHING, NY. 11355 U.S.A. " TEL (718) 461-7000 " FAX (718) 767-1102 http://www.kepcopower.com " email: hq@kepcopower.com...
  • Page 11: Klp Outline Dimensions

    FIGURE 4. KLP OUTLINE DIMENSIONS (SHEET 1 OF 2) KEPCO, INC. " 131-38 SANFORD AVENUE " FLUSHING, NY. 11355 U.S.A. " TEL (718) 461-7000 " FAX (718) 767-1102 http://www.kepcopower.com " email: hq@kepcopower.com 070113 228-1616 REV 7...
  • Page 12: Http://Www.kepcopower.com " Email: Hq@Kepcopower.com

    FIGURE 4. KLP OUTLINE DIMENSIONS (SHEET 2 OF 2) KEPCO, INC. " 131-38 SANFORD AVENUE " FLUSHING, NY. 11355 U.S.A. " TEL (718) 461-7000 " FAX (718) 767-1102 http://www.kepcopower.com " email: hq@kepcopower.com 228-1616 REV 7 070113...

Table of Contents