Sterilization Mode; Quiet Operation - Panasonic WH-MDC05F3E5 Service Manual

Hide thumbs Also See for WH-MDC05F3E5:
Table of Contents

Advertisement

12.11 Sterilization Mode

Purpose:
To sterilize water tank by setting the required boiling temperature.
o
Control start condition:
Tank connection menu is set to YES by control panel.
o
Sterilization menu is set to YES by control panel.
o
Sterilization signal received from control panel by timer.
o
Control stop condition:
After sterilization timer completed or
o
After 4 hours of operation since sterilization function starts.
o
Control content:
Once the sterilization function is enable, set the target sterilization set temperature.
o
Booster heater will allow to ON during solar SET condition.
o
Booster heater OFF Temp = Sterilization set temperature +0°C
Booster heater ON Temp = Sterilization set temperature -7°C
Sterilization timer which set by control panel will start count after tank achieve sterilization set temperature.
o
Target tank temperature will set back to normal tank set temperature.
o
* Tank heater control is not affected by solar pump when solar priority set.

12.12 Quiet Operation

Purpose:
To provide quiet operation compare to normal operation by reduces outdoor unit noise.
o
Starting condition:
When quiet button is presses.
o
When quiet is request to ON by weekly timer. (Refer to control panel)
o
When any of above mentioned condition is achieved, this control is activated.
New target FM speed = Present target FM speed – 80 rpm
Minimum target FM speed = 200 rpm
Cancellation condition:
Cancel by pressing quiet button.
o
Stop by OFF/ON button
o
When quiet is request to OFF by weekly timer.
o