Configuration mode.

The configuration mode is used to set the RAK148D2 and RAK164D2
to match the heating/cooling system. These thermostats function
with up to 2-stage heat pump systems (RAK148D2 only).
To configure the RAK148D2 and RAK164D2, perform the
following steps:
Note: Operation being set will blink in the display.
1. Slide the Function switch to the OFF position.
2. Remove the thermostat's front cover.
3. To enter the configuration mode, simultaneously hold
the LEFT and RIGHT buttons in for 6 seconds while the
thermostat is in OFF mode. (See diagram on page 3.)
4. Once in the configuration mode, press the
to change settings within each screen.
- Press the RIGHT button to advance to the next screen.
- Press the LEFT button to return to the previous screen.
NOTE: To exit configuration mode at any time, slide the
Function switch to Heat or Cool.
Configuration Mode Settings
The setup screens for Configuration Mode are as follows:
1.
Fahrenheit or Celsius.
Press the
to select.
Press the RIGHT button to advance to the next screen.
NOTE: Default factory setting is Fahrenheit.
2.
Set the number of degrees between the
"setpoint" temperature and the
"turn on" temperature for first stage.
Press the
Press the RIGHT button to advance to the next screen.
Note: Default factory setting is 2°F/1°C for each stage.
8
or
button
or
button to set differential value.
Choose
or
button