Download Print this page

The Source SOURCE04BLP Owner's Manual page 23

Advertisement

13
Installing Cooking Components
Important: Before cooking on your grill the first
time, wash the Cooking Grids with warm, soapy
water. Rinse and dry thoroughly. Season with
cooking oil regularly. After cooking is completed,
turn grill to HIGH setting for about five minutes to
burn off excess grease or food residue.
1.
Place the Steel Flame Tamers on the lower
ledge above Burners.
Evenly space the Cooking Grids on the ledge
2.
above the Flame Tamers.
Place the Secondary Cooking Rack into the
3.
slots on the upper left and upper right of Grill
Bowl Panels.
LP Gas Model Only
14
Connecting A Liquid Propane Gas
(LP gas) Tank To Your Grill
Open the front Doors of cabinet. Pull out the
1.
Tank Pull-Out Tray. Place a 20 lb tank with
foot ring into the hole in the tray. Make sure
the tank valve is in the OFF positon. (Turn
clockwise to close.) Align the tank so the
Tank Valve faces the rear right corner of
cabinet. Use provided Wing Bolt to secure
gas tank. See
1ST
2.
Check the tank valve to ensure it has proper
external mating threads to fit the hose &
regulator assembly provided. (Type 1 connec-
tion per ANSI Z21.58b-2002)
Be sure all Burner Valves are in the OFF
3.
position.
4.
Inspect the valve connection port and regulator
assembly. Look for damage or debris. Remove
any debris. Inspect hose for damage. Never
use damaged or plugged equipment.
5.
When connecting the regulator assembly to
the tank valve, hand tighten nut clockwise to
a full stop. See
wrench to tighten because it could damage
the Quick Coupling Nut and result in a
hazardous condition.
6.
Open the tank valve fully (counterclockwise).
Use a soapy water solution to check all
connections for leaks before attempting to light
your grill. See "Checking for LP Gas Leaks"
on
page
24. If a leak is found, turn the tank
valve off and do not use your grill until the
leak is repaired.
DO NOT use a
2ND
SECON DARY
COOKING RACK
COOKING GRID
STEEL FLAME
TAMER
SLOTS FOR
RACK
1ST
2ND
QUICK
COUPLING
NUT
Type 1 connection
per ANSI Z21.58b-2002
CAUTION: When the appliance is not in use, the
gas must be turned off at the supply tank.
Disconnecting A Liquid Propane Gas
(LP gas) Tank From Your Grill
Turn the Burner Valves and LP gas tank valve
1.
to the full OFF position. (Turn clockwise to
close.)
Detach the hose and regulator assembly from
2.
the LP gas tank valve by turning the Quick
Coupling Nut counterclockwise.
23

Advertisement

loading

Related Products for The Source SOURCE04BLP

This manual is also suitable for:

Source04bng