Firmware Pages and Descriptions
System Connection Page Elements (Cont.)
Ethernet Mode
MAC Address
Master Connection:
ICSNET/Ethernet/USB
Mode
System Number
Master IP/URL
Master Port Number
Username/Password
Refer to the Step 2: Choosing a Master Connection Mode Setting section on page 60 for more detailed
information on using the System Connection page.
100
Sets the speed of the Ethernet connection to the panel.
• Choices are: Auto, 10 Half Duplex, 10 Full Duplex, 100 Half Duplex, or
100 Full Duplex.
Displays a read-only field that is factory set by AMX for the built-in Ethernet
interface.
Sets the NetLinx Master communication values:
Sets the NetLinx Master to communicate with the panel via either ICSNET or
Ethernet. This is based on the cable connection from the rear.
• ICSNet is a CAT-5 cable (terminated in an RJ-45 connector) used to distribute
communications between the NetLinx Master and the panel. ICSNet differs
from Ethernet in that ICSNet can provide power to any connected devices.
• Ethernet is a CAT-5 cable (10/100Base T terminated in an RJ-45 connector)
used to network computers together and is used in most LAN (local area
networks). This description is also used to refer to both wired and wireless
communication.
• USB option cannot be used on Modero panels which are not equipped with a
rear USB port.
Cycles between the different connection modes (URL, Listen, and Auto)
(ETHERNET Only)
• URL - In this mode, enter the IP/URL, Master Port Number, and Username/
Password (if used) on the Master.
- The System Number field is read-only because the panel obtains this
information from the communicating Master.
• Listen - In this mode, add the Modero panel address into the URL List in
NetLinx Studio and set the connection mode to Listen. This mode allows the
Modero touch panel to "listen" for the Master's communication signals.
- The System Number and Master IP/URL fields are red-only.
• Auto - In this mode, enter the System Number and a username/password
(if applicable). This mode is used when both the panel and the NetLinx
Master are on the same Subnet and the Master has its UDP feature enabled.
- Master IP/URL field is read-only.
Allows you to enter a system number.
• Default value is 0 (zero). (ETHERNET Only)
Sets the Master IP or URL of the NetLinx Master.
(ETHERNET Only)
Allows you to enter the port number used with the NetLinx Master.
• Default value is 1319. (ETHERNET Only)
If the target Master has been previously secured, enter the alpha-numeric string
(into each field) assigned to a pre-configured user profile on the Master.
This profile should have the pre-defined level of access/configuration rights.
CV17 17" Modero Coor Video Touch Panels