Section   2 a:     P OU   I nstallation  
 
 
Required   M aterials   a nd   T ools  
 
Lavit   E CO3   F ilter   K it  
¼"   N SF   a pproved   w ater   t ubing   ( black   c olor   r ecommended)  
40   p si   p ressure   r educing   v alve   ( ¼"   q uick   c onnect   f ittings   r ecommended)  
¼'   I n   l ine   c heck   v alve  
¼"   S hut   o ff   v alve  
Tubing   c utter  
 
 
 
Dispensers   i n   a   P OU   i nstallation   m ust   b e   c onnected   t o   a   k nown   p otable  
water   s upply.   I t   i s   r ecommended   t hat   t he   p ower   c ord   b e   c onnected   t o   a  
GFI   o utlet.  
         
 
 
 
 
Installation   I nstructions  
 
1. Ensure   t hat   t he   m inimum   w ater   i nlet   p ressure   f rom   t he   m ains   s upply   i s   2 8   p si.   C onnect   t o  
the   w ater   s upply   u sing   a   s tandard   t hree   w ay   v alve   c onnected   t o   a n   u nder   s ink   c old   w ater  
shut   o ff   v alve   o r   c onnect   i n   a nother   a cceptable   m anner   t o   a llow   f or     ¼ "   w ater   t ubing   t o   b e  
connected.   R un   t he   t ubing   t o   t he   d ispenser   s o   t hat   t here   i s   e nough   e xcess   t ubing   t o   a llow  
movement   o f   t he   d ispenser   f or   s ervice   i n   p lace.  
 
2. Properly   s ecure   t he   t ubing   w ith   a ppropriate   f asteners   t o   m inimize   t he   p ossibility   o f   t he  
tubing   b eing   p ulled   o ff   t he   m ains   c onnection   a nd   t o   p rovide   a n   a esthetic   i nstallation   f or   t he  
customer.  
 
3. Install   t he   4 0   p si   p ressure   r educing   v alve,   t he   i n   l ine   c heck   v alve,   a nd   t he   s hut   o ff   v alve   o n  
the   w ater   i nlet   t ubing.   F rom   t he   m ains   c onnection   i t   i s   r ecommended   t hat   t he   s equence   i s  
the   P RV   f ollowed   b y   t he   c heck   v alve   a nd   t hen   t he   s hut   o ff   v alve.   A s   a n   o ption   a   s econd   s hut  
off   v alve   c an   b e   i nstalled   p rior   t o   t he   P RV   t o   a llow   t he   r emoval   o f   a ll   d ownstream  
components.  
 
4. Flush   t he   L avit   E CO3   f ilter   o utside   o f   t he   d ispenser   t o   e nsure   n o   c arbon   f ines   c an   e nter   t he  
dispenser.  
 
 