If the power is cut or the device is switched off while the firmware is being updated (SE-700
M/B/setup/upgrade), this will cause corrupted data on the SD Card and thus the SE-700 will then fail to
boot. The SD card will need to be re-programmed.
Q: I cannot roll back to older SE-700 SW versions.
Yes, this is because the system structure has been modified, if you have used SE-700_v0.9.9.4 and above,
you will not be able to roll back to older versions.
Q: On the control panel, F3 button does not have any function.
F3 button has been defined as "Restoring to Default" in V_1.0.0.0.
i. Pressing F3 button while in the second level sub-option of one particular function resets all
parameters of that sub-option to default.
ii. Pressing F3 button in the first level option of that particular function resets all parameters of that
option to default.
Q: What are the options under Outputs/Audio/Level in the MENU?
AUTO, SMPTE and EBU are the three sub-options available for the option Analog Audio Level. Three
different digital audio level specifications give the user flexibility to choose whether to use the American
Standard or the European Standard. If AUTO is selected, then the SE-700 will automatically use
i. SMPTE SPEC (-24 dBFS) when the resolution settings are 1080i/59.94/60 and 720P/59/60; and
ii. EBU SPEC (-18 dBFS) when the resolution settings are 1080i/50 and 720p/50.
Q: Under the option Setup/Standard, 1080i/50 mode is selected and nothing is seen on the HDMI
output to Datavideo's TVS-1000.
When the SE-700 is set to 1080i, the HDMI output resolution will be set to 1080p, which is not supported
on the TVS-1000 and this is why you cannot see anything on the screen.
Q: Under the option Outputs/HDMI PORT, assign the output to be PGM SOURCE but it will be
automatically switched back multiviewer.
The SE-700 output consists of two SDI OUT and one HDMI OUT, and if the system detects that all three
outputs are set to sources other than multiviewer, the system will then force to reset the HDMI OUT to
multiviewer.
Q: When PIP PGM and PIP PVW buttons are turned on at the same time, PIP is not displayed on PVW
screen, and if only the PIP PGM button is turned on, PIP is seen on both PGM and PVW screens. The
same issue occurs in KEYER and DSK.
The SE-700 exhibits different behaviors from the SE-2200.
Turning on PIP PVW/KEYER PVW/DSK PVW displays the effect on the PVW screen. Turn on the PVW, and
after the effect is configured, turn on PIP PGM/LUMA PGM/DSK PGM to take the effect to PGM view.
(The user can also use the CUT button or T-BAR to perform the transition. If only the PIP PGM/KEYER
PGM/DSK PGM is turned on, you will see the effect on both PVW and PGM views.)
Q: PIP image does not fill the PIP screen.
When X = 0, Y = 0, and Size = 100%, PIP image fails to fully fill the PIP screen (or the initial position is
incorrect), a few lines will appear at the bottom and when switched to underscan mode, the top and
bottom of the background image on the PIP screen can be seen through.
Q: In the Still option, images are sometimes distorted if they are captured from live video fed into
Inputs 1-4.
It is recommended to use still images in the Still option.