Electrical Connection - Miele W 6073 Operating Instructions Manual

Hide thumbs Also See for W 6073:
Table of Contents

Advertisement

Notes for the installer
Drainage
- Machines with a Drain Pump
The machine drains via a drain pump with a
delivery head of 1 metre. The 1.5 m long
drain hose must not be kinked as this re-
stricts drainage. The swivel elbow at the end
of the hose can be turned or detached.
Drainage possibilities:
^ Direct into a sink: (for the drain pump ver-
sion). Hook the hose over the edge and
secure.
Make sure the water can flow away freely
to avoid flooding and to prevent water from
being sucked back into the machine.
^ Connection to a standpipe.
^ Connection to a plastic drain pipe with a
rubber nipple. There is no need for a
non-return valve.
^ drainage via a floor drain (gully).
- Machines with a Drain Valve
The machine empties through a motor con-
trolled drain valve. A DN 50 angle connector
can be used to make connection to an
on-site drainage system, (sink box with
odour trap).
Coin mechanism unit
The washer-extractor can be fitted with a
coin unit.
It can also be connected to an existing coin
unit. The correct connection cable is re-
quired for this. For the C 4030 / 4031,
C 4050 / 4051 et C 4065 / 4070 using timed
operation an AD 3 adapter is required.
The machine has to be reprogrammed for
this connection. This must only be done by a
Miele authorized service engineer.
The coin unit and connection cable are
available at extra cost from the Miele Spare
Parts Department, or from Miele specialist
dealers.
32

Electrical connection

All electrical work must be carried out by a
suitably competent person in compliance
with national and local regulations.
Please take note of the Installation diagram
and the Wiring diagram. They are important
for electrical connection.
The electrical safety of this machine is in ac-
cordance with IEC 335.
The minimum suds level required for activat-
ing the heating is given in mm column of wa-
ter: W 6073 45 mm column of water
The voltage and frequency are given on the
data plate. The machine must only be con-
nected if these match the mains supply.
Variants: 3N AC 380-415 V 50 Hz
3
AC 220-240 V 50 Hz
3
AC 440
1
AC 220-240 V 50 Hz
The motor is fitted with an overload protec-
tion switch.
For extra safety it is advisable to install a re-
sidual current device with a trip current of 30
mA.
Nominal rated load and fuse rating are given
on the data plate. Ensure that these are
compatible with the electricity supply.
WARNING
THIS APPLIANCE MUST BE EARTHED
Connection should be made via a suitable
isolator which complies with national and lo-
cal regulations, and the on/off switch should
be easily accessible for servicing work.
When installation and connection have
been completed all removable outer pan-
els must be re-fitted before the machine is
operated.
V 60 Hz
M.-Nr. 06 006 840