Levelling
The machine must stand level to ensure
smooth operation.
The adjustable feet can compensate for an
uneven base.
^ Screw the foot or feet out until the machine
stands level.
^ Hold the foot tight using a pipe wrench.
^ Tighten the counternut using a screwdriver
as indicated.

Connection to water supply

Connection must be made to the water sup-
ply via a stopcock which conforms with local
and national regulations. This work must be
carried out by a suitably qualified and com-
petent person.
Water Supply (Water Fittings) Regulations
1999 and Water Byelaws 2000, Scotland
The Type A air gap fitted to the machine pro-
vides Category 5 protection thereby en-
abling connection to mains water. The air
gap is located upstream of the detergent
box and to provide protection against the
possibility of backflow of cleaning agents the
machine is supplied with 2 double check
valves which should be connected to the in-
let hoses.
M.-Nr. 06 006 840
Notes for the installer
To ensure the machine is correctly con-
nected please observe the installation plan
and the installation instructions supplied with
the machine.
See the installation diagram supplied for in-
structions on connection to the water supply
and for drainage.
The inlet pressure hoses supplied with the
machine must be used for connection to the
water supply.
To ensure the hot water inlet hose (marked
90°C) lasts for many years it is advised not
to use it on a hot water connection supplying
water hotter than 70°C.
If replacing an inlet hose only use a hose
able to withstand a burst pressure of at least
70 bar and a temperature of 90°C. This also
applies to all connection parts.
Miele "Original" spare parts meet this re-
quirement.
A water pressure flow rate of at least 1 bar,
maximum 10 bar is essential to ensure the
smooth operation of this machine.
Water taken into the machine must not ex-
ceed a temperature of 70°C.
Connection to cold water only
-See the Installation Plan provided.