14. POSITION OF PATTERN INDICATION PLATE
(B338 ⋅ B346 ⋅ B347 ⋅ B348 ⋅ B349)
STANDARD
Each pattern on indication plate should be indicated at the center of the indication window.
ADJUSTMENT
1. Set pattern dial to zigzag stitch and check baseline on selecting cam which should meet with upper end
of release lever.
2. Loosen two screws on indication gear.
3. Set the symbol of zigzag stitch at the center of the indication window by turning indication gear.
4. Tighten two screws.
NOTE
After adjustment, make sure each pattern is indicated at the center of the indication window by turning
pattern dial.
- 36 -