5.6.10 Display Setup Menu

The Display Setup Menu allows you to change the color scheme of the Fish Finder display,
adjusts the chart scrolling rate, enables or disables the White Line and allows determining the
graphical representation of fishes.
[MENU] + "Display Setup" + [ENTER]
Color Settings
Scrolling Speed
White Line
Fish Symbols
Water Temperature

5.6.11 Transducer Setup Menu

The Transducer Setup menu contains settings that does not require frequent changes.
[MENU] + "Transducer Setup" + [ENTER]
Keel Offset
Calibrate Sound Speed
Calibrate Water Speed
Calibrate Water Temperature
Calibrate Aux Temperature
Restore Defaults
Sonar Resolution
80
- User Manual
Allows you to change the color scheme of the Fish Finder display.
The available colors are Blue Background, White Background, Black
Background, Gray Scale and Reversed Gray Scale.
Adjusts the chart scrolling rate. Note that the scrolling rate is limited by
the sound speed and the depth according with the following relation:
the deeper the setting, the slower the scrolling rate. 100% is the
maximum possible.
Controls how the chart plotter displays information about the bottom
type (hard or soft).
Allows determining the graphical representation of underwater
suspended targets: Echo/Echo+Icon/Echo+Icon+Depth/Echo+Depth/
Icon/Icon+Depth. The Fish icons displayed are among four different
shapes depending on the size of the Target (Small, Med, Big, Huge).
Allows you to choose the Water Temperature label displayed over the
echogram between Primary and External.
It is the transducer depth offset from the surface. This makes
it possible to measure depth from the surface instead of from
the transducer's location.
Allows calibrating the value of Sound Speed in the water,
depending on the water temperature and salinity.
Allows calibrating the value of Water Speed sensor. The
calibration value, in the range between -10% to +10%, will
be applied to the water speed from the transducer.
Allows the calibration on the Water Temperature sensor.
Using the readings from a precise temperature measuring
device, insert here a positive/negative offset to display right
value on Fish Finder screens.
Allows the calibration of the Aux Temperature sensor. Using
the readings from a precise temperature measuring device,
insert here a positive/negative offset to display right value on
FF screens.
Restores the default values.