CHARGING PROGRAMS AND OPTIONS COMBINATIONS
DESULPHATION
15.8V
15.8V
+
15.8V
+
RECOND
15.8V
+
+
RECOND
15.8V
15.8V
+
15.8V
+
RECOND
15.8V
+
+
RECOND
Limit:
14 • EN
20018888A MUS 4.3 Test&Charge, Manual, Print file.indd 14
SOFT START
BULK
0.8A until 12.6V
Increasing voltage to
14.4V. 0.8A
0.8A until 12.6V
Increasing voltage to
14.7V. 0.8A
0.8A until 12.6V
Increasing voltage to
14.4V. 0.8A
0.8A until 12.6V
Increasing voltage to
14.7V. 0.8A
4.3A until 12.6V
Increasing voltage to
14.4V. 4.3A
4.3A until 12.6V
Increasing voltage to
14.7V. 4.3A
4.3A until 12.6V
Increasing voltage to
14.4V. 4.3A
4.3A until 12.6V
Increasing voltage to
14.7V. 4.3A
Max 8h
Max 20h
ABSORPTION
ANALYSE
Declining current
Checks if voltage
14.4V
drops to 12V
Declining current
Checks if voltage
14.7V
drops to 12V
Declining current
Checks if voltage
Max 15.8V
14.4V
drops to 12V
0.3A
Declining current
Checks if voltage
Max 15.8V
14.7V
drops to 12V
0.3A
Declining current
Checks if voltage
14.4V
drops to 12V
Declining current
Checks if voltage
14.7V
drops to 12V
Declining current
Checks if voltage
Max 15.8V
14.4V
drops to 12V
1.5A
Declining current
Checks if voltage
Max 15.8V
14.7V
drops to 12V
1.5A
30 min or 4h
Max 10h
3 minutes
depending on
battery voltage
RECOND
FLOAT
13.6V
12.7V–14.4V
0.8A
0.8–0.4A
13.6V
12.7V–14.7V
0.8A
0.8–0.4A
13.6V
12.7V–14.4V
0.8A
0.8–0.4A
13.6V
12.7V–14.7V
0.8A
0.8–0.4A
13.6V
12.7V–14.4V
4.3A
4.3A–2A
13.6V
12.7V–14.7V
4.3A
4.3A–2A
13.6V
12.7V–14.4V
4.3A
4.3A–2A
13.6V
12.7V–14.7V
4.3A
4.3A–2A
10 days
Charge cycle
Charge cycle
restarts if
restarts if
voltage drops
voltage drops
PULSE
2013-01-15 16:28:32
Need help?