Solar Panel Instructions - Mighty Mule FM402 Installation Manual

Table of Contents

Advertisement

NEVER USE TRANSFORMER AND SOLAR PANEL(S) AT THE SAME TIME!
IMPORTANT INFORMATION ABOUT LOW VOLTAGE WIRE:
The only wire acceptable for use with GTO products is 16 gauge stranded, low voltage, PVC sheathed wire. This
particular gauge enables the solar panel to provide an adequate charge through the control board to the battery
at distances up to 250'.
DO NOT use telephone wire or solid core wire. Unlike stranded wire, these types of wire are inadequate for use
with your gate opener system.
Step 1
Make sure the power switch is OFF.
Step 2
Strip 3/16" off the ends of the low voltage wire and twist tightly. Attach
these ends to the 14VAC OR SOLAR terminals located on the terminal
block. Be certain not to let the exposed wires touch each other!
BATT +
Step 3
WHT
K3
GRN
RED
Insert one solar panel wire into a 14VAC OR
K4
BLK
SOLAR terminal. Insert the other solar panel
14 VAC
OR
wire into the remaining 14VAC OR SOLAR
SOLAR
Low Voltage Wire
VAR6
from Transformer
terminal. The wires can be connected to the
or Solar Panel
ON OFF
14VAC OR SOLAR terminals regardless of
color/polarity.
Step 4
Tighten set screws against exposed end of wires. A dab of household
petroleum jelly on each terminal will help prevent corrosion.
NOTE: For multiple panels, wire the panels in
parallel as shown in this diagram.
rev 12-14-15

Solar Panel Instructions

It will damage the control board!
Solar Panels connect in PARALLEL
RED
BLACK
ON/OFF
Switch
ON/OFF
OPEN < JOG > CLOSE
PWR.
RED
BLACK
Mighty Mule FM402 Installation Instructions
STATUS
1st OPR.
2nd OPR.
MIN
MAX OFF
120
SEC.
STALL FORCE
AUTO CLOSE
SET
LIMIT
REMOVE JUMPER FOR
PUSH TO OPEN OPTION
SFTY.
JP1
VAR1
EXIT
VAR2
CYCLE
VAR3
EDGE
VAR4
SENSOR
COMMON
VAR5
LOCK+
LOCK–
PF1
K1
WHT
GRN
K2
RED
BLK
BATT +
BATT –
WHT
K3
GRN
RED
K4
BLK
14 VAC
OR
SOLAR
VAR6
ON OFF
Low Voltage Wire from
Transformer or Solar
21

Advertisement

Table of Contents
loading