Connect Opener Power Cables

Step 1
Bring FIRST power cable into the control box through a strain relief slot,
leaving enough wire to reach the FIRST OPR. terminal block.
Insert the individual power cable wires into appropriate terminals on the
FIRST OPR. terminal block (white to WHT; green to GRN; red to RED;
black to BLK). Tighten the set screws. A dab of petroleum jelly on each
terminal will help prevent corrosion.
Step 2
Pull the 36' second opener power cable through the PVC conduit and
secure in the driveway slot/trench (see pages 6 and 14).
Step 3
Insert the SECOND power cable into a strain relief slot at the bottom
of the control box, leaving enough wire to reach the SECOND OPR.
terminal block.
Insert the individual power cable wires into appropriate terminals on
the SECOND OPR. terminal block (white to WHT; green to GRN; red to
RED; black to BLK). Tighten the set screws.

Connect the Transformer

NEVER USE TRANSFORMER AND SOLAR PANEL(S) AT THE SAME TIME!
IMPORTANT INFORMATION ABOUT LOW VOLTAGE WIRE:
The only wire acceptable for use with GTO products is 16 gauge stranded, low voltage, direct burial wire. This
particular gauge enables the transformer to provide an adequate charge through the control board to the battery
at distances up to 1000'.
DO NOT use telephone wire or solid core wire. Unlike stranded wire, these types of wire are inadequate for use
with your gate opener system.
NEVER splice wires together. Splicing permits corrosion and seriously degrades the wire's ability to carry an
adequate current.
Step 1
Make sure the power switch is OFF.
Step 2
Select the electrical outlet where you will plug the transformer. Measure
the distance from this outlet to the control box following the path
where the wire will be laid. After you have measured how much wire is
needed, cut the wire to the appropriate length (up to 1000').
14
Mighty Mule FM402 Installation Instructions
Correct
Wrong
Wire Terminal
Screwed into
Block
wire insulation.
(*Solar Instructions on Page 21)
1st OPR.
OPEN < JOG > CLOSE
2nd OPR.
SET
PWR.
LIMIT
FIRST Opener
Strain Relief Slots
Power Cable
SECOND Opener
Power Cable
Wrong
Exposed strands
of wire.
STATUS
MIN
MAX OFF
120
SEC.
STALL FORCE
AUTO CLOSE
REMOVE JUMPER FOR
PUSH TO OPEN OPTION
SFTY.
JP1
VAR1
EXIT
VAR2
CYCLE
VAR3
EDGE
VAR4
SENSOR
COMMON
VAR5
LOCK+
LOCK–
PF1
K1
WHT
GRN
K2
RED
BLK
BATT +
BATT –
WHT
K3
GRN
RED
K4
BLK
14 VAC
OR
SOLAR
VAR6
ON OFF
(Battery Wires Not Shown)
ON/OFF
Switch
ON/OFF
rev 12-14-15