Evaporator Coil
Condenser Coil
Figure 3-29 Upper Scroll & Control Box
Cover Removed
3.6.3 Condenser Fan Assembly Removal
To remove condenser fan assembly, do the following:
a. Perform steps outlined in Section 3.6.2.
b. Depress
and
remove
Figure 3-30).
c. Using both hands, carefully pull up on fan assembly
until it is free of the motor shaft.
d. When replacing the fan assembly make sure the fan
assembly is against the stop on the shaft (See
Figure 3-31)
e. Push back on tab to allow fan assembly to rest
against stop (See Figure 3-32). Fan assembly will
now be flush with the end of the motor shaft.
f. Reverse above procedure for reassembly.
Retaining
Ring
(See
Figure 3-30 Condenser Fan Assembly
& Retaining Ring
Condenser Motor
13MM
Bolt
Figure 3-31 Condenser Fan Motor
& Fan Assembly Stop
Figure 3-32 Condenser Fan Motor
& Fan Assembly Tab
3-11
Retaining
Ring
Fan Stop
13MM
Bolt
Grommet
Tab
T--298