Open the installer connection side (2) to
carry out the electrical connections.
5.8.2 Connection to the PCB
1
2
30 mm max.
Legend
1
Terminal block
2
Electrical wires
3
Sheath
Warning ! When connecting electrical
cables to the terminal block on the PCB:
•
Keep a 30 mm maximum distance
between the terminal block (1) and the
stripped sheath (3).
•
Otherwise, fasten the electrical wires
(2) together with a cable tie.
•
Secure the cables with the electrical
box cable clamp.
5.8.3 Separation of high and low
voltage cables
Legend
1
Main board
2
Passage for high voltage
3
Passage for low voltage
•
Respect passage (2) for low voltage
cables and (3) for high voltage cables.
3
1
2
3
5.8.4 External controls connection
5
1
4
3
2
Legend
1
Neutral
2
Room Thermostat
3
Live
4
Frost Protection
5
Link wire
Important ! Remove link wire (5) when
fitting external controls.