Piping
installation
Connect the A elbow
Ø 22 mm to a discharge
system leading to the
sewer, in compliance with
the instructions below:
- Use a rigid PVC tube or a
flexible silicon pipe resistant
to condensate.
Condensate
- The pipe must have a
discharge
continuous fall.
elbow.
- Do not use copper pipes
Important notice :
The float of the condensate
recovery system also
ensures fume tightness.
Therefore, it is useless to
add water in the
condensate box.
38
Condensate box with
access plugs for cleaning
purposes.
A
YES
NO
Electrical
connection
Electrical components have
been tested to meet the
equivalent requirements of
the BEAB.
Do not interrupt the mains
supply with a time switch or
programmer.
Connection of the whole
electrical system and any
heating system controls to
the electrical supply must be
through a common isolator.
Isolation should preferably
be by a double pole
switched fused spur box
having a minimum contact
separation of 3mm on each
WARNING : This appliance
pole. The fused spur box
must be earthed.
should be readily accessible
and preferably adjacent to
This appliance must be
the boiler. It should be
wired in accordance with
identified as to its use.
these instructions. Any fault
arising from incorrect wiring
cannot be put right under
the terms of the
Saunier Duval guarantee.
All system components
must be of an approved
type.
Mains Cable
Important: If a replacement
supply cable is required it
must be purchased from
Saunier Duval.
• The 630 mA fuse of the
PCB must be connected to
the neutral.
39