14.2 Removable plate / Silencer
1
2
3
4
Legend
1
Upper silencer
2
Upper silencer retaining screw
3
Lower silencer
4
Removable plate
14.2.1
Removable plate
•
Remove the removable plate (4) by
pulling towards you.
14.2.2
Silencer
•
Remove the removable plate (4).
•
Disconnect the lower silencer (3).
•
Remove the upper silencer retaining
screw (2).
•
Remove the upper silencer (1).
•
If necessary, clean the inside of the 2
silencers using a dry cloth taking care
not to damage the foam.
•
Repeat the above operations in reverse
to reassemble the unit.
14.3 Condensate trap
1
2
3
4
Legend
1
Condensate trap retaining clips
2
Condensate trap
3
Condensate outlet
4
Outlet siphon
•
Drain the filling siphon of the
condensate trap (see chapter on "Filling
the condensate trap").
•
Disconnect the outlet pipe located
under the condensate trap (2).
•
Disconnect the condensate trap pipe
located under the combustion chamber
(see chapter on "Spare parts").
•
Remove the condensate trap by
releasing the retaining clips (1) and
taking care not to spill any liquid.
•
Clean the pipes and remove any debris.
•
Clean the condensate trap by rinsing
under water.
•
Reassemble the unit taking care to
position the sealing gaskets correctly
and to fill the filling siphon according
to the chapter on "Filling of the
condensate trap".
37
3