Vicon Roughneck V910 Installation & Operation Manual

Vicon Roughneck V910 Installation & Operation Manual

Impact-resistant dome cameras

Advertisement

XX137-00-03
V910 IMPACT-RESISTANT
DOME CAMERAS
Vicon Industries Inc. does not warrant that the functions contained in this equipment will meet
your requirements or that the operation will be entirely error free or perform precisely as
described in the documentation. This system has not been designed to be used in life-critical
situations and must not be used for this purpose.
Copyright © 2004 Vicon Industries Inc. All rights reserved.
Product specifications subject to change without notice.
Vicon and its logo are registered trademarks of Vicon Industries Inc.
VICON INDUSTRIES INC., 89 ARKAY DRIVE, HAUPPAUGE, NEW YORK 11788
TEL: 631-952-CCTV (2288) FAX: 631-951-CCTV (2288) TOLL FREE: 800-645-9116
24-Hour Technical Support: 800-34-VICON (800-348-4266)
UK: +44 (0) 1489 566300
WEB: www.vicon-cctv.com
Vicon part number 8009-8137-00-03
Rev 504 Section 3

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Roughneck V910 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Vicon Roughneck V910

  • Page 1 V910 IMPACT-RESISTANT DOME CAMERAS Vicon Industries Inc. does not warrant that the functions contained in this equipment will meet your requirements or that the operation will be entirely error free or perform precisely as described in the documentation. This system has not been designed to be used in life-critical situations and must not be used for this purpose.
  • Page 3: Fcc Notice

    FCC Notice Note: Complies with Federal Communications Commission Rules & Regulations Part 15, Subpart B for a Class A digital device. WARNING This equipment generates and uses radio frequency energy and if not installed and used properly, that is, in strict accordance with the manufacturer’s instruction, may cause interference to radio and television reception.
  • Page 4 20. Replacement Parts - Use only Vicon specified replacement parts or an approved equivalent to prevent unit damage and 6. Attachments - Use only Vicon recommended attachments to injury.
  • Page 5: Table Of Contents

    Switch Settings .............................8 Lens/Autoiris Adjustment ..........................8 Final Installation ............................10 Operation ...........................11 Maintenance ........................11 Care and Cleaning of Lower Dome......................11 Shipping Instructions .......................12 Coaxial Cable Recommendations..................13 Twisted-Pair Cable ......................14 Technical Information .......................15 Contents • i XX137-00-03 Rev 504 Roughneck V910 Dome Cameras...
  • Page 6: Quick Installation

    Quick Installation For experienced installers, use the installation diagram below. For complete detailed instructions on how to install the V910, read the Installation section. Installation Diagram ii • Quick Installation XX137-00-03 Rev 504 Roughneck V910 Dome Cameras...
  • Page 7: Introduction

    Introduction The information in this manual covers the installation, operation, and maintenance of the Roughneck V910 Series of Impact-Resistant Dome Cameras. These units should only be installed by a qualified technician using approved materials in accordance with national, state and local wiring codes. Read this manual through completely before attempting installation.
  • Page 8: Installation

    Installation Unpacking and Inspection All Vicon equipment is tested and inspected before leaving the factory. It is the carrier’s responsibility to deliver the equipment in the same condition as it left the factory. Inspection for Visible Damage Immediately inspect the cartons upon delivery. Make a note of any visible damage on all copies of the carrier’s freight bill.
  • Page 9 Figure 1 Exploded View (Heater on Outdoor Models only) Installation • 3 XX137-00-03 Rev 504 Roughneck V910 Dome Cameras...
  • Page 10: Accessory Kit

    Accessory Kit There is an accessory kit included with all configurations of Roughneck V910. The table below lists the contents. Description Quantity Tamperproof driver bit, ¼ hex T-15 (to remove tamperproof screws) Pipe sealant (to seal area where base meets...
  • Page 11 Refer to Figure 3 for installation options. Note: For outdoor installations, Vicon recommends that the vent plug should only be used if fogging conditions exist. Additionally, if the side cable access hole is used, the base must be mounted so the hole is pointed directly downward.
  • Page 12: Cable Connections

    (P8) on the PC board. This signal is polarized and specific wire connection is necessary. See Table below. Twisted Pair Connections (P8) Pin Number Function Video Video GND Figure 4 Camera/Lens PC Board 6 • Installation XX137-00-03 Rev 504 Roughneck V910 Dome Cameras...
  • Page 13: Camera Power Connections

    Voltage irregularities such as surges, drops, and interruptions can affect the operation of your equipment and, in severe cases, damage certain components. Vicon strongly recommends the use of line conditioners, voltage regulators, and uninterruptible power supply (UPS) systems.
  • Page 14: Camera Synchronization

    Refer to Figure 6. Tu rning the potentiometer opens and closes the iris to regulate light extremes. Turning the potentiometer clockwise opens the iris wider, allowing more light. 8 • Installation XX137-00-03 Rev 504 Roughneck V910 Dome Cameras...
  • Page 15 Figure 6 Location of Autoiris Potentiometer Figure 7 Switch Settings Installation • 9 XX137-00-03 Rev 504 Roughneck V910 Dome Cameras...
  • Page 16: Final Installation

    Any alignment of holes and screws is acceptable. The cover can be rotated 90° by aligning the screws/holes differently. 10 • Installation XX137-00-03 Rev 504 Roughneck V910 Dome Cameras...
  • Page 17: Operation

    Operation When power is applied to the camera, the Roughneck V910 views the selected scene. Maintenance The Roughneck V910 Impact-Resistant Cameras require no scheduled maintenance except for the occasional cleaning of the lower dome. Care and Cleaning of Lower Dome The inside surface of the smoked (gray-tinted) dome is easily scratched.
  • Page 18: Shipping Instructions

    Shipping Instructions Use the following procedure when returning a unit to the factory: 1. Call or write Vicon for a Return Authorization (R.A.) at one of the locations listed below. Record the name of the Vicon employee who issued the R.A.
  • Page 19: Coaxial Cable Recommendations

    Coaxial Cable Recommendations Caution: Careful selection of proper cable is essential to obtain the best performance from this equipment. Vicon assumes no responsibility for poor performance when cables other than those recommended, or equivalent, are installed. In all cases, coaxial cable impedance should be 75 ohms.
  • Page 20: Twisted-Pair Cable

    Twisted-Pair Cable Caution: Careful selection of the proper cable is essential to obtain the best performance from this equipment. Vicon assumes no responsibility for poor performance when cables other than those recommended are installed. Materials Use a pure copper stranded or solid conductor with or without a tin plating to obtain a low DC resistance. Do not use cable with either steel or aluminum stranded conductor because these do not transfer signals effectively for long distances.
  • Page 21: Technical Information

    Heater: 2-pin connector. Video Output pedance: 75 ohms. Scanning System: EIA/NTSC: 52 5 lines, 60 fields/sec. CCIR/PAL: 625 lines, 50 fields/sec. adio F equen mission Rating: FCC Class A. Technical Information • 15 XX137-00-03 Rev 504 Roughneck V910 Dome Cameras...
  • Page 22 -40 to 150° F (-40 to 65° C). Storage Humidity: Up to 90% relative, nonconde nsing. Wind Load: Outdoor: Heavy rain or snow driven b y winds up to 80 mph. 16 • Technical Information XX137-00-03 Rev 504 Roughneck V910 Dome Cameras...
  • Page 23 106° - 47.6.4° 78.2°- 35.8° V910VF-CA/-C/V910VFT-CA/-C 2.6 - 6 varifocal with autoiris 106° - 47.6.4 78.2°- 35.8° V910VF-DN/V910VF-DN-C 2.6 - 6 varifocal with autoiris 82.05° - 38.26 60.32°- 28.66° Technical Information • 17 XX137-00-03 Rev 504 Roughneck V910 Dome Cameras...
  • Page 24: Vicon Standard Equipment Warranty

    Software supplied either separately or in hardware is furnished on an “As Is” basis. Vicon does not warrant that such software shall be error (bug) free. Software support via telephone, if provided at no cost, may be discontinued at any time without notice at Vicon’s sole discretion.
  • Page 25 Vicon Industries Inc. Corporate Headquarters 89 Arkay Drive Hauppauge, New York 11788 631-952-CCTV (2288) 800-645-9116 Fax: 631-951-CCTV (2288) Vicon Europe Headquarters Brunel Way Fareham, PO15 5TX United Kingdom +44 (0) 1489 566300 Fax: +44 (0) 1489 566322 Brussels Office Planet II - Unit E...

Table of Contents