USING C-GRYPHON BATTERY CHARGER

C-GRYPHON is a battery charger for Gryphon™ M Series readers.
The LEDs signal the C-GRYPHON status, as described in the following table:
LED
Power
on/Data
Charging
Charge
completed
Charging +
Charge
completed
Reconditioning battery
button
Power on/Data
(yellow LED)
After many recharging cycles NiMh and NiCd batteries may tend to lose their
operating autonomy. This condition can be overcome by placing the
Gryphon™ M Series reader onto the C-GRYPHON charger and pressing the
"battery reconditioning" button.
Yellow On = C-GRYPHON is powered.
Yellow Blinking = C-GRYPHON receives commands
from the Host.
Red On = the battery charge is in progress
Red Blinking = the battery reconditioning is in progress.
Green On = the battery is completely charged.
Red and Green Blinking together = the reader is not
correctly placed onto the charger.
STATUS
Charging
(red LED)
Charge completed
(green LED)