MTU 12V2000G65 Operating Instructions Manual page 51

Table of Contents

Advertisement

Fault
code no.
Full designation
203
SD T-Charge Air
205
SD T-Coolant Intercool-
er
208
SD P-Charge Air
211
SD P-Lube Oil
215
SD P-HD
216
SD T-Lube Oil
219
SD T-Intake Air
220
SD Level Coolant Wa-
ter
223
SD Level Coolant Inter-
cooler
Meaning
SD alarm configuration,
charge-air temperature sen-
sor faulty, short circuit or
wire break.
SD alarm configuration, cool-
ant temperature sensor of in-
tercooler faulty, short circuit
or wire break.
SD alarm configuration,
charge-air pressure sensor
faulty, short circuit or wire
break.
SD alarm configuration, lube-
oil pressure sensor faulty,
short circuit or wire break.
SD alarm configuration, rail
pressure sensor faulty, HP
controller in emergency
mode, short circuit or wire
break.
SD alarm configuration, lube-
oil temperature sensor faulty,
short circuit or wire break.
SD alarm configuration, in-
take air temperature sensor
faulty, short circuit or wire
break.
SD alarm configuration, cool-
ant level sensor faulty, short
circuit or wire break.
SD alarm configuration, cool-
ant level sensor faulty, short
circuit or wire break.
MS15018/03E 2016-02 | Troubleshooting | 51
Setting parame-
Action
ter no.
Check sensor and
1.8004.571
wiring (B9), replace
as necessary.
Check sensor and
1.8004.574
wiring (B26), replace
as necessary.
Check sensor and
1.8004.566
wiring (B10), replace
as necessary.
Check sensor and
1.8004.563
wiring (B5), replace
as necessary.
Check sensor and
1.8004.567
wiring (B48), replace
as necessary.
Check sensor and
1.8004.575
wiring (B7), replace
as necessary.
Check sensor and
1.8004.573
wiring (B3), replace
as necessary.
Check sensor and
1.8004.584
wiring (F33), replace
as necessary. Fault
is rectified when
electronics are
switched back on
Check sensor and
1.8004.583
wiring (F57), replace
as necessary. Fault
is rectified when
electronics are
switched back on.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents