■ SERVICE PRECAUTIONS / サービス時の注意事項
Safety measures
Some internal parts in this product contain high voltages
and are dangerous.
Be sure to take safety measures during servicing, such
as wearing insulating gloves.
Note that the capacitors indicated below are dangerous
even after the power is turned off because an electric
charge remains and a high voltage continues to exist
there.
Before starting any repair work, connect a discharging
resistor (5 k-ohms/10 W) to the terminals of each
capacitor indicated below to discharge electricity.
The time required for discharging is about 30 seconds
per each.
C309, C310, C317 to C320, C327 and C328
For details, refer to "PRINTED CIRCUIT BOARDS".
Precaution for handling measuring instrument
Since the speaker output of this unit is BALANCED OUT
connected, the ground side of the measuring instrument
to be connected to the speaker terminal MUST be kept in
floating condition.
10
安全対策
・ この製品の内部には高電圧部分があり危険です。修理
・ 下記のコンデンサには電源を OFF にした後も電荷が残
on MAIN (3) P.C.B.
計測機器取り扱い上の注意
本機のスピーカー出力は BALANCED OUT 接続となってい
ますので、スピーカー端子に接続する計測器のアース側
はフローティング状態に保つ必要があります。
の際は、絶縁性の手袋を使用するなどの安全対策を
行ってください。
り、高電圧が維持されており危険です。
修理作業前に放電用抵抗(5 k Ω /10 W)を下記の各コ
ンデンサの端子間に接続して放電してください。
放電所用時間は各々約 30 秒間です。
MAIN(3)P.C.B. の C309、C310、
C317 ∼ C320、C327、C328
詳しくは PRINTED CIRCUIT BOARDS を参照してくだ
さい。