Pressure Switch:
From the Electronical Card:
CN2.10 – CN2.2
ELECTRONIC CARD
CONNECTOR
Above sketch show the connectors of the pressure switch on the electronical card. Probes of
the tester should be applied on to the related connectors.
From the component:
Probes of the tester should be applied on to the related connectors as shown on the pictures.
0
There is water (Full)
∞
There is not water (Empty)
- 63 -