Precaution:
Always remove the plug from the power socket before touching internal
components.

Washing Pump:

From the Electronical Card:
You can only measure the primary winding value from the electronical card. Resistance
value of the primary winding must be 95
on the connectors CN2.3 – CN2.9.
Above sketch show the connectors of the washing pump on the electronical card. Probes of
the tester should be applied on to the related connectors.
From the component:
Measurement of the primary
Measurement of the secondary
windings of the washing pump
windings of the washing pump
(
(white cable – blue cable)
Probes of the tester should be applied on to the related connectors as shown on the pictures.