Drain Pump:

From the Electronical Card:
143 ± 7
on the connectors CN2.2 – CN2.4
Above sketch show the connectors of the drain pump on the electronical card. Probes of the
tester should be applied on to the related connectors.
From the component :
Probes of the tester should be applied on to the related connectors as shown on the pictures
- 59 -