Harvest Control; Full Bin Control - Cornelius IACS224 Installation Manual

224 series
Hide thumbs Also See for IACS224:
Table of Contents

Advertisement

1. Thinner Bridge - Turn the ice thickness "pot" adjustment screw Ø CW one full turn.. Allow two cycles be-
fore determining if additional adjustments are required.
2. Thicker Bridge - turn the ice thickness "pot" adjustment screw Ù CCW on full turn. Allow two cycles before
determining if additional adjustments are required.
NOTE:
Never judge the thickness of the ice from the first batch of ice produced - the first cycle is a
balance cycle. Always wait for the second cycle before making and adjustments.

HARVEST CONTROL

An ice harvest switch bar is used to control the harvest cycle. It is operated by the movement of the ice from
evaporator. The momentary opening of the ice harvest switch terminates the ice machine's harvest cycle.. As
the ice harvest bar swings closed, the ice machine returns into the freezing cycle.

FULL BIN CONTROL

A bin thermostat is provided to control the level of the ice in the storage bin. When the storage bin is full, the bin
thermostat tube equipped inside the storage bin will sense a low temperature which causes the bin thermostat
to switch to it "close" position. The ice machine will complete the cycle and shut off.
The ice machine remains off until sufficient ice is removed from the storage bin allowing the bin thermostat tube
to warm up. As the bin thermostat tube senses a warm temperature which causes the bin thermostat to switch
back to its "open" position, the ice machine starts to make ice.
The setting of bin thermostat can be adjusted by turning the dial on the top of thermostat to"CW" to cold position
or to "CCW" to warm position. In the mid-range position the bin thermostat will close at about 42_F.
13