Indication Lamps - CTEK MXTS 70 Quick Manual

Hide thumbs Also See for MXTS 70:
Table of Contents

Advertisement

INDICATION LAMPS, DISPLAyS
AND ERRORCODES
MXTS 70
MXTS 70
12V/70A
MXTS 70
START
MODE
24V/35A
PAUSE
12V/70A
24V/35A
MXTS 70
AGM
AGM
NORMAL
Ca/Ca

INDICATION LAMPS:

GEL
POWER
12V/70A
START/PAUSE LAMP
START
24V/35A
Indicates that charging has not started or has been interrupted.
MODE
MXTS 70
PAUSE
Press START/PAUSE-button to start/resume.
POWER LAMP
12V/70A
Amp
Indicates that mains supply is connected.
MODE
24V/35A
AGM
AGM
ORMAL
Ca/Ca
ERROR LAMP
GEL
POWER
1
2
Amp
3
4
Indicates that a fault has occurred.
ODE
Se ERROR CODES for description.
Press START/PAUSE-button to clear error and interrupt charging.
AGM
SUPPLY
POWER
TEMPERATURE SENSOR LAMP
Amp
Indicates that the temperature sensor is activated.
M
Voltage is automatically adjusted to optimize charge at
SUPPLY
WER
ambient temperature.
1
2
3
4
5
6
REDUCED CURRENT LAMP
Amp
Indicates that the maximum current is limited.
SUPPLY
V
4
5
6
7
8
5
6
7
8
SUPPLY
h
5
6
7
8
V
A
A
6
7
8
h
Ah & info
A
Ah & info
SET
A
20015126D Manual MXTS70, All languages, Print file 003.indd 5
12V/70A
24V/35A
12V/70A
24V/35A
Amp
SUPPLY
SETTINGS BEFORE START:
DISPLAy (V)
Amp
Indicates voltage set
Options: 12/24 Volts
DISPLAy (A)
Indicates current set
Options: 70/50/40/30/20 A in 12V setting
Options: 35/25/20/15/10 A in 24V setting
SUPPLY
70A/35A could only be selected for Supply program.
5
6
7
8
For Normal-, Ca/Ca-, AGM/GEL- and AGM Power-program maximum
current is 50A/25A.
DISPLAy (h)
Indicates which parameter to set
Options: U/A/
DISPLAy (Ah & info)
Displays error codes
7
8
REAL TIME INDICATION DURING ChARGING:
A
DISPLAy (V)
Displays output voltage
DISPLAy (A)
Displays output current
DISPLAy (h)
Alt. 1. Displays total elapsed charging time (minutes/hours)
Ah & info
Alt. 2. Displays time elapsed until error occured
DISPLAy (Ah & info)
Alt.1. Displays total charge delivered since start (minutes/hours)
Alt.2. Displays error codes together with ERROR lamp
SET
V
12/24
10-70
V
A
E01-E99
h
h
Ah & info
SET
A
E01
Ah & info
ERROR CODES:
E01
REVERSE POLARITy
Connect the charger according to "CONNECT THE CABLES"
E02
OVER VOLTAGE
Battery voltage to high for the chosen charging program, check
battery voltage.
E03
TIME OUT STEP 1: DESULPhATION
SET
Restart the charger. If charging is still being interrupted the bat-
tery is seriously sulphated and may need to be replaced.
E04
TIME OUT STEP 2: SOFT START
Restart the charger. If charging is still being interrupted the battery
can not accept charge and may need to be replaced.
E05
TIME OUT STEP 5: ANALySE
Restart the charger. If charging is still being interrupted the bat-
tery can not keep charge and may need to be replaced.
E06
BATTERy OVERhEATED
The battery is too hot to charge. The battery is damaged and
may need to be replaced.
E07
LOW BATTERy VOLTAGE IN SUPPLy PROGRAM
Battery voltage too low or too large consumers connected. Check
if 12V battery connected in 24V battery setting or disconnect
large consumers.
E08
hIGh CURRENT IN SUPPLy PROGRAM
Check if clamps are short circuited or connected reversed polarity.
E99
OVER VOLTAGE PROTECTION
If battery voltage is below 17V the ERROR lamp is lit when 24V
setting has been selected.
A lt 1. Press START/PAUSE button to charge with 12V setting.
To set the parameters for customized charging proceed with
"CHARGING" step 5 to 8
Alt 2. Press INCREASE or DECREASE button to change to
24V setting. Press START/PAUSE button to resume. To set the
parameters for customized charging proceed with "CHARGING"
step 5 to 8.
EN • 5