2 Maintenance, Adjustments and Check Points

2.1.

Preventive Maintenance

Preventive maintenance is performed at specific intervals, and consists of machine cleaning, and parts
replacement. It is essential to perform these service activities properly, and at the specified intervals for
customer satisfaction.
The purpose of this service is to maintain machine performance, and image quality.
1.
You should prepare the replacement parts, and cleaning tools beforehand.
2. After completing the preventive maintenance, discard the used parts and packaging in accordance with
local regulations, and clean the surrounding area.
3. Before servicing the equipment, turn the power switches Off, and disconnect the power cord from the
wall outlet.
4. Before using solvents such as IPA (Isopropyl alcohol), wear rubber gloves and eye protection.
2.1.1.
Timing
1. Perform the preventive maintenance in accordance with the Preventive Maintenance Check List (refer
to 2.4.) in the service manual.
2.1.2.
Cleaning the Rollers
1. Rollers should be cleaned with water, and a clean cloth.
2. Use the IPA (Isopropyl Alcohol) sparingly.
2.1.3.
Precautions for Disassembly, and Adjustment
Caution:
Turn the Power Switch on the Left Side, and the Main Power Switch on the Back of the
machine to the OFF position, and then unplug the AC Power Cord before disassembling the
machine.
1. After taking the unit apart, do not attempt to operate the machine.
2. When operating the machine with covers removed, be careful and avoid clothing from being caught by
moving components.
3. While the electricity is applied to the unit, do not connect nor disconnect the connectors on any PC
Board.
4. When handling the drum, follow the precautions listed in section 2.3..
5. Ensure to use correct screws.
6. Use toothed lock washers for the installation of ground wires to ensure electrical continuity.
7. To reassemble, reverse the sequence of disassembly, unless otherwise specified.
8. Blown fuses should only be replaced with fuses of the same specified rating.
2.1.4.
Precautions for Handling Lasers
The optical laser system employed by this photocopier is completely sealed by a protective housing, and an
external cover. Therefore, the laser beam will not stray, or leak during photocopying operation.
However, when servicing the photocopier, take the following precautions:
1. Do not insert any screwdrivers, or other tools that have high reflective properties into the path of the
laser.
2. Before servicing the photocopier, take off any watches, rings, or other metallic objects that you may be
wearing. (This is to avoid the danger of the laser entering the eye by reflecting off the metallic objects
being worn.)
Since the laser beam cannot be seen with the naked eye, please follow the above precautions for
maximum safety.
Ver. 1.1