Bosch VEZ-400 Series Installation Manual page 31

Autodome 4000 mini ptz dome
Hide thumbs Also See for VEZ-400 Series:
Table of Contents

Advertisement

AUTODOME 4000 Mini PTZ Dome
No1
Off
Off
Table 6.7: Camera Protocol Setting (No. 1 & 2, Dip Switch SW303)
No3
Off
Off
On
On
Table 6.8: Camera Baud Rate Setting (No. 3 & 4, Dip Switch SW303)
No5
Off
On
Table 6.9: Camera's RS-485 Termination Setting (No. 5, Dip Switch SW303)
Notice!
When the RS-485 signal is looped through, make sure that (only) the last device is properly
terminated. Improper RS-485 wiring or termination may result in unreliable system operation.
Bosch Security Systems, Inc.
No2
Protocol
On
Bosch OSRD*
Off
Pelco-D/Pelco-P
No4
Baud Rate (bps)
Off
2400
On
4800
Off
9600*
On
38400
Termination
Off
On*
Installation Manual
Connection | en
31
2015.08 | | Wall + Pipe Mounts