Enabling The Dedicated Ilo Management Port; Non-Hot-Plug Power Supply - HP ProLiant ML310e Gen Maintenance And Service Manual

Hide thumbs Also See for ProLiant ML310e Gen:
Table of Contents

Advertisement

Remove the iLO module from the chassis.
7.
To replace the component, reverse the removal procedure.

Enabling the dedicated iLO management port

The onboard NIC 1/shared iLO connector is set as the default system iLO port.
To enable the installed dedicated iLO module:
During the server startup sequence after module installation, to access iLO RBSU, press the F8 key.
1.
Select the Network menu.
2.
Click the Network Interface Adapter field.
3.
To change the setting to ON, press the spacebar.
4.
To save the new settings, press the F10 key.
5.
Select the File menu, and then to close iLO RBSU, click Exit.
6.
To confirm exiting iLO RBSU, click OK. The server automatically reboots.
7.
IMPORTANT:
lost. Access the physical machine, and then set the Network Interface Adapter field to ON.

Non-hot-plug power supply

To remove the component:
Power down the server (on page 26).
1.
Remove all power:
2.
Disconnect each power cord from the power source.
a.
Disconnect each power cord from the server.
b.
Unlock the tower bezel.
3.
Remove the access panel
4.
If the iLO RBSU settings are reset to the default values, access to the machine will be
("Access
panel" on page 31).
Removal and replacement procedures 51