Technical Information 19.2010
Customer complaint
Check water connection / screen and
clean if necessary, see
Leak testing: Engine switched off,
connect machine to water supply
(e. g., pressurized water tank)
Disconnect machine from water
supply. Connect power adapter,
b
see
5.2
Blip the (+) button on the control panel
several times in succession,
b
see
1.1.2
Blip the (–) button on the control panel
several times in succession,
b
see
1.1.2
Blip the (OFF) button on the control
b
panel, see
1.1.2
1) : Frequency increases until the solenoid valve is all the way open; when the solenoid valve is all the way open, no more clicking can
be heard
2) : If the electronics detect a defective control panel, then the solenoid valve is opened all the way during use, thus ensuring the flow
of water
TI_19_2010_30_01_01.fm
Customer complaint
b
1.1.4
System free of leaks?
Can the clicking of the
solenoid valve be heard?
Can the clicking of the
solenoid valve be heard?
Generator / wiring harness defective,
yes
remedied?
no
yes
yes
1)
Does frequency
increase?
yes
Does frequency
decrease?
yes
no
repair or replace
Troubleshooting completed
no
Leaky solenoid valve, repair or
replace
no
Solenoid valve / control defective,
repair or replace if necessary
no
2)
Control panel
/ button / wiring
harness defective, repair or replace
no
2)
Control panel
/ button / wiring
harness defective, repair or replace
yes
2)
Control panel
/ button / wiring
harness defective, repair or replace
Page 5