Fault
code no.
Full designation
472
AL Stop SD
474
AL Wiring FO
475
AL CR Trigger Engine
Stop
476
AL Crash Rec. Init. Er-
ror
478
AL Comb. Alarm Yel
(Plant)
479
AL Comb. Alarm Red
(Plant)
480
AL Ext. Engine Protec-
tion
555
AL Call MTU Field Serv-
ice
Meaning
Engine stop as shutdown
channels have "sensor fault"
(alarm configuration parame-
ter, see PR 2.8008.100 for
explanation).
Line break or short circuit at
channel FO (alarm configura-
tion parameter, see PR
2.8008.100 for explanation).
Tripped by crash recorder
triggering due to engine shut-
down.
Initialization error of crash re-
corder.
YELLOW combined alarm
from plant (alarm configura-
tion parameter, see PR
2.8008.100 for explanation).
RED combined alarm from
plant (alarm configuration pa-
rameter, see PR 2.8008.100
for explanation).
External engine protection
function active (alarm config-
uration parameter, see PR
2.8008.100 for explanation).
Power reduction caused by
maintenance function (main-
tenance concept, alarm con-
figuration parameter, see PR
2.8008.100 for explanation).
MS15018/02E 2013-09 | Troubleshooting | 63
Setting parame-
Action
ter no.
Contact Service.
2.8006.593
Contact Service.
2.8006.655
Replace engine gov-
1.8010.009
ernor at next oppor-
tunity.
Contact Service.
1.8010.007
Contact Service.
2.8006.001
Contact Service.
2.8006.002
Contact Service.
2.0291.921
Contact Service.
2.0555.001