Fault
code no.
203
205
208
211
215
216
219
220
223
48 | Troubleshooting | MS15018/02E 2013-09
Full designation
Meaning
SD T-Charge Air
SD alarm configuration,
charge-air temperature sen-
sor faulty, short circuit or
wire break.
SD T-Coolant Intercool-
SD alarm configuration, cool-
er
ant temperature sensor of in-
tercooler faulty, short circuit
or wire break.
SD P-Charge Air
SD alarm configuration,
charge-air pressure sensor
faulty, short circuit or wire
break.
SD P-Lube Oil
SD alarm configuration, lube-
oil pressure sensor faulty,
short circuit or wire break.
SD P-HD
SD alarm configuration, rail
pressure sensor faulty, HP
controller in emergency
mode, short circuit or wire
break.
SD T-Lube Oil
SD alarm configuration, lube-
oil temperature sensor faulty,
short circuit or wire break.
SD T-Intake Air
SD alarm configuration, in-
take air temperature sensor
faulty, short circuit or wire
break.
SD Level Coolant Wa-
SD alarm configuration, cool-
ter
ant level sensor faulty, short
circuit or wire break.
SD Level Coolant Inter-
SD alarm configuration, cool-
cooler
ant level sensor faulty, short
circuit or wire break.
Setting parame-
Action
ter no.
Check sensor and
1.8004.571
wiring (B9), replace
as necessary.
Check sensor and
1.8004.574
wiring (B26), replace
as necessary.
Check sensor and
1.8004.566
wiring (B10), replace
as necessary.
Check sensor and
1.8004.563
wiring (B5), replace
as necessary.
Check sensor and
1.8004.567
wiring (B48), replace
as necessary.
Check sensor and
1.8004.575
wiring (B7), replace
as necessary.
Check sensor and
1.8004.573
wiring (B3), replace
as necessary.
Check sensor and
1.8004.584
wiring (F33), replace
as necessary. Fault
is rectified when
electronics are
switched back on
Check sensor and
1.8004.583
wiring (F57), replace
as necessary. Fault
is rectified when
electronics are
switched back on.