MTU 12 V 2000 G25 Operating Instructions Manual page 50

Table of Contents

Advertisement

Fault
code no.
270
301
302
303
304
305
306
307
50 | Troubleshooting | MS15018/02E 2013-09
Full designation
Meaning
SD Frequency Input
SD alarm configuration, fre-
quency input faulty, short cir-
cuit or wiring damage.
AL Timing Cylinder A1
Time-of-flight measuring fault
injector cylinder A1: Time-of-
flight value measured ex-
tremely small or large (alarm
configuration parameter, see
PR 2.8008.100 for explana-
tion).
AL Timing Cylinder A2
Time-of-flight measuring fault
injector cylinder A2 Time-of-
flight value measured ex-
tremely small or large (alarm
configuration parameter, see
PR 2.8008.100 for explana-
tion).
AL Timing Cylinder A3
Time-of-flight measuring fault
injector cylinder A3: Time-of-
flight value measured ex-
tremely small or large (alarm
configuration parameter, see
PR 2.8008.100 for explana-
tion).
AL Timing Cylinder A4
Time-of-flight measuring fault
injector cylinder A4 Time-of-
flight value measured ex-
tremely small or large (alarm
configuration parameter, see
PR 2.8008.100 for explana-
tion).
AL Timing Cylinder A5
Time-of-flight measuring fault
injector cylinder A5 Time-of-
flight value measured ex-
tremely small or large (alarm
configuration parameter, see
PR 2.8008.100 for explana-
tion).
AL Timing Cylinder A6
Time-of-flight measuring fault
injector cylinder A6 Time-of-
flight value measured ex-
tremely small or large (alarm
configuration parameter, see
PR 2.8008.100 for explana-
tion).
AL Timing Cylinder A7
Time-of-flight measuring fault
injector cylinder A7 Time-of-
flight value measured ex-
tremely small or large (alarm
configuration parameter, see
PR 2.8008.100 for explana-
tion).
Setting parame-
Action
ter no.
Contact Service.
2.8006.590
Replace plug-in
1.8004.500
pump if this occurs
frequently.
Replace plug-in
1.8004.501
pump if this occurs
frequently.
Replace plug-in
1.8004.502
pump if this occurs
frequently.
Replace plug-in
1.8004.503
pump if this occurs
frequently.
Replace plug-in
1.8004.504
pump if this occurs
frequently.
Replace plug-in
1.8004.505
pump if this occurs
frequently.
Replace plug-in
1.8004.506
pump if this occurs
frequently.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents