Room Sealed Flue Options; Short Parts List Bentone Sterling - Worcester GREENSTAR UTILITY 18/25 Instruction Manual

Floor standing oil fired condensing boiler conventional flue & room sealed flue
Table of Contents

Advertisement

8 716 106 256 C 03.10
30/3/10
L = 140 - 390mm
A
L = 4000mm
A
B
125mmØ x4
L = 3000mm
A
B
125mmØ x3
C
L = 3000mm
A
B
125mmØ x3
D
D
L = 3000mm
A
B
125mmØ x3
C
18

ROOM SEALED FLUE OPTIONS

14:24
Page 18
L
L = 2000mm
125mmØ x2
L
L = 6000mm
E
B
125mmØ x6
L
L = 5000mm
E
L
B
125mm• x4
L = 5000mm
L
E
B
T
125mmØ x5
INSTALLATION & SERVICING INSTRUCTIONS FOR WORCESTER GREENSTAR DANESMOOR UTILITY 18/25
ROOM SEALED FLUE OPTIONS
L
The diagrams (opposite) show the components
used and the maximum flue length (L) for
A
each flue configuration.
In all cases L is measured from the outside of
the boiler casing.
B
• To achieve the maximum flue length (L), a flue
section will have to be reduced in length.
• Only the flue terminal or straight flue
C
extensions can be reduced in length by
x2
cutting.
• The flue terminal end can be fitted from the
inside or outside of the building.
IMPORTANT: All horizontal sections must
rise away from the boiler by 52mm per
metre (3°) to allow the condensate to
drain back to the boiler.
L
A - Horizontal terminal
B - Straight flue extension
C - Flue bend 90°
D - Flue bend 45°
E - Vertical Terminal Kit (incl. 90° elbow)
Calculating the flue length:
Measure the total flue length required, noting
that the maximum straight flue length including
the terminal is:
Horizontal 80/125mmØ: 4000mm (excluding
120mm of terminal extending outside the building)
Vertical 80/125mmØ: 6000mm (measured from
the boiler top panel).
Then reduce the total straight flue length for
each extra flue bend (excluding the vertical flue
L
kit 90° elbow) by:
1000mm for 90°
500mm for 45°
D
D
Flue Extension lengths:
Horizontal & Vertical 80/125mmØ: 1000mm
overall length.
Effective length when engaged into sockets
within the flue run is 950mm.
Flue Terminal lengths:
Horizontal 80/125mmØ: 350-450/460-670 mm
Vertical 80/125mmØ: 1080mm + cage
* to outside wall.
L
A
C
D
B
8 716 106 256C (03/2010)
E

Hide quick links:

Advertisement

Table of Contents