Summary of Contents for Daikin FTX50GV1B

  • Page 1: Operation Manual

    DAIKIN ROOM AIR CONDITIONER MODELS FTX50GV1B Operation Manual FTX60GV1B FTX71GV1B English Deutsch Français Nederlands Español Italiano ΕλληνικÜ Portugues Рóссêий Türkçe...
  • Page 2: Table Of Contents

    CONTENTS READ BEFORE OPERATION Safety precautions ......... 2 Names of parts..........4 Preparation Before Operation ......7 OPERATION AUTO · DRY · COOL · HEAT · FAN Operation ............. 10 Adjusting the Air Flow Direction ....12 POWERFUL Operation ........ 14 OUTDOOR UNIT QUIET Operation.....
  • Page 3: Safety Precautions

    • Do not attempt to repair, relocate, modify or reinstall the air conditioner by yourself. Incorrect work will cause electric shocks, fire etc. For repairs and reinstallation, consult your Daikin dealer for advice and information. • The refrigerant used in the air conditioner is safe. Although leaks should not occur, if for some reason any refrigerant happens to leak into the room, make sure it does not come in contact with any flame as of gas heaters, kerosene heaters or gas range.
  • Page 4: Installation Site

    • Do not block air inlets nor outlets. Impaired air flow may result in insufficient performance or trouble. • Do not stand or sit on the outdoor unit. Do not place any object on the unit to avoid injury, do not remove the fan guard. •...
  • Page 5: Names Of Parts

    Names of parts ■ Indoor Unit...
  • Page 6: Outdoor Unit

    ■ Outdoor Unit 50/60 class 71 class ■ Indoor Unit 1. Air filter 14. HOME LEAVE lamp (red): • Lights up when you use HOME LEAVE 2. Titanium Apatite Photocatalytic Operation. (page 16.) Air-Purifying Filter 15. Indoor Unit ON/OFF switch: 3.
  • Page 7: Remote Controller

    ■ Remote Controller CANCEL TIMER < > ARC433B70 1. Signal transmitter: 8. QUIET button: OUTDOOR UNIT QUIET • It sends signals to the indoor unit. operation (page 15.) 2. Display: 9. FAN setting button: • It displays the current settings. •...
  • Page 8: Preparation Before Operation

    Preparation Before Operation ■ To set the batteries Position + and – correctly! 1. Slide the front cover to take it off. 2. Set two dry batteries AAA.LR03 (alkaline). 3. Set the front cover as before. ATTENTION ■ About batteries •...
  • Page 9 Preparation Before Operation ■ To operate the remote controller • To use the remote controller, aim the transmitter at the indoor unit. If there is anything to block signals between the unit and the remote controller, such as a curtain, the unit will not operate. •...
  • Page 10: Operation

    ■ To set the clock 1. Press “CLOCK button”. is displayed. blinks. 2. Press “TIMER setting button” to set the clock to the present time. Holding down “ ” or “ ” button rapidly increases or decreases the time display. 3.
  • Page 11: Auto · Dry · Cool · Heat · Fan Operation

    OPERATION AUTO · DRY · COOL · HEAT · FAN Operation The air conditioner operates with the operation mode of your choice. From the next time on, the air conditioner will operate with the same operation mode. ■ To start operation 1.
  • Page 12: To Change The Air Flow Rate Setting

    ■ To change the air flow rate setting 5. Press “FAN setting button”. DRY mode AUTO or HEAT or COOL or FAN mode Five levels of air flow rate setting from “ ” to “ ” plus “ ” “ ”...
  • Page 13: Adjusting The Air Flow Direction

    Adjusting the Air Flow Direction You can adjust the air flow direction to increase your comfort. ■ To adjust the horizontal blade (flap) 1. Press “SWING button ”. • “ ” is displayed on the LCD and the flaps will begin to swing. 2.
  • Page 14 ■ To 3-D Airflow 1. 3. Press the “SWING button ” and the “SWING button ”: the “ ” and “ ” display will light up and the flap and louvers will move in turn. ■ To cancel 3-D Airflow 2.
  • Page 15: Powerful Operation

    POWERFUL Operation POWERFUL operation quickly maximizes the cooling (heating) effect in any operation mode. You can get the maximum capacity. ■ To start POWERFUL operation 1. Press “POWERFUL button”. • POWERFUL operation ends in 20 minutes. Then the system automatically operates again with the settings which were used before POWERFUL operation.
  • Page 16: Outdoor Unit Quiet Operation

    OUTDOOR UNIT QUIET Operation OUTDOOR UNIT QUIET operation lowers the noise level of the outdoor unit by changing the frequency and fan speed on the outdoor unit. This function is convenient during night. ■ To start OUTDOOR UNIT QUIET operation 1.
  • Page 17: Home Leave Operation

    HOME LEAVE Operation HOME LEAVE operation is a function which allows you to record your preferred temperature and air flow rate settings. ■ To start HOME LEAVE operation 1. Press “HOME LEAVE button”. • “ ” is displayed on the LCD. •...
  • Page 18: Use As Energy-Saving Mode

    ■ What’s the HOME LEAVE operation? Is there a set temperature and air flow rate which is most comfortable, a set temperature and air flow rate which you use the most? HOME LEAVE operation is a function that allows you to record your favorite set temperature and air flow rate.
  • Page 19: Intelligent Eye Operation

    INTELLIGENT EYE Operation “INTELLIGENT EYE” is the infrared sensor which detects the human movement. ■ To start INTELLIGENT EYE operation 1. Press “SENSOR button”. • “ ” is displayed on the LCD. ■ To cancel the INTELLIGENT EYE operation 2. Press “SENSOR button” again. •...
  • Page 20 “INTELLIGENT EYE” is useful for Energy Saving. ■ Energy saving operation • Change the temperature –2°C in heating / +2°C in cooling / +1°C in dry mode from set temperature. • Decrease the air flow rate slightly in fan operation. (In FAN mode only) Notes on “INTELLIGENT EYE”...
  • Page 21: Timer Operation

    TIMER Operation Timer functions are useful for automatically switching the air conditioner on or off at night or in the morning. You can also use OFF TIMER and ON TIMER in combination. ■ To use OFF TIMER operation • Check that the clock is correct. If not, set the clock to the present time.
  • Page 22: To Use On Timer Operation

    ■ To use ON TIMER operation • Check that the clock is correct. If not, set the clock to the present time. (page 9.) 1. Press “ON TIMER button”. is displayed. blinks. 2. Press “TIMER Setting button” until the time setting reaches the point you like.
  • Page 23: Care And Cleaning

    CARE Care and Cleaning CAUTION Before cleaning, be sure to stop the operation and turn the breaker OFF. Units ■ Indoor unit, Outdoor unit and Remote controller 1. Wipe them with dry soft cloth. ■ Front panel 1. Open the front panel. •...
  • Page 24: Air Filter

    Filters 1. Open the front panel. (page 22.) 2. Pull out the air filters. • Push a little upwards the tab at the center of each air filter, then pull it down. 3. Take off the Titanium tabs (3 tabs at top) Apatite Photocatalytic Air-Purifying Filter.
  • Page 25: Before A Long Idle Period

    NOTE • Operation with dirty filters: (1) cannot deodorize the air. (2) cannot clean the air. (3) results in poor heating or cooling. (4) may cause odour. • To order Titanium Apatite Photocatalytic Air-Purifying Filter contact to the service shop there you bought the air conditioner.
  • Page 26: Trouble Shooting

    TROUBLE SHOOTING Trouble Shooting These cases are not troubles. The following cases are not air conditioner troubles but have some reasons. You may just continue using it. Case Explanation Operation does not start soon. • This is to protect the air conditioner. •...
  • Page 27: Check Again

    These cases are not troubles. The following cases are not air conditioner troubles but have some reasons. You may just continue using it. Case Explanation ■ After operation is stopped: The outdoor fan rotates while the air conditioner is not in •...
  • Page 28: Call The Service Shop Immediately

    Call the service shop immediately. WARNING ■ When an abnormality (such as a burning smell) occurs, stop operation and turn the breaker OFF. Continued operation in an abnormal condition may result in troubles, electric shocks or fire. Consult the service shop where you bought the air conditioner. ■...
  • Page 29: On Cancel

    Fault diagnosis. FAULT DIAGNOSIS BY REMOTE CONTROLLER In the ARC433 series, the temperature display sections on the main unit indicate corresponding codes. 1. When the TIMER CANCEL button is held down for 5 seconds, a “ ” indication flashes on the temperature display section.
  • Page 30 Two-dimensional bar code is a code for manufacturing. 3P190111-3D M09B273 (1002) HT...

This manual is also suitable for:

Ftx60gv1bFtx71gv1b

Table of Contents