Code 39 Check Digit Verification

Parameter # 30h
When this feature is enabled, the imager checks the integrity of all Code 39 symbols to verify that the data
complies with specified check digit algorithm. Only Code 39 symbols which include a modulo 43 check digit are
decoded. Enable this feature if the Code 39 symbols contain a Modulo 43 check digit.
Enable Code 39 Check Digit
(01h)

Transmit Code 39 Check Digit

Parameter # 2Bh
Capture a bar code below to transmit Code 39 data with or without the check digit.
Transmit Code 39 Check Digit (Enable)
(01h)
NOTE Code 39 Check Digit Verification must be enabled for this parameter to function.
*