  • Page 1 PORTATIF JENERATÖR KULLANIM VE BAKIM KITABI PORTABLE GENERATOR USER & MAINTENANCE MANUAL AAP 1000...
  • Page 2 Adres/Adress: Murat Bey Beldesi Güney Girişi Cad. No:8 34540 Çatalca / İstanbul T: + 90 212 887 11 11 F: + 90 212 887 10 20 e-mail: info@aksaservis.com.tr...
  • Page 5: Safety Information

    1. SAFETY INFORMATION EXHAUST FUMES ARE POISONOUS. 1.1. Never operate engine indoors. FUEL IS HIGHLY INFLAMMABLE. 1.2. Stop engine when refueling. 1.3. No smoking while refueling. 1.4. Take care not to spill fuel. 1.5. Never operate in rain or snow. - 1 -...
  • Page 6 1.6. Avoid placing inflammables. 1.7. Keep away more than 1 meter. 1.8. Never touch with wet bands. 1.9. Ground (earth) generator. 1.10. Do not connect to commercial power outlet. Do not connect with another. 1.11. Use oil-mixed gasoline if not, engine will be overheated. 1.12.
  • Page 7: Pre-Operation Check

    2. PRE-OPERATION CHECK Fuel tank capacity :4L Shake fuel tank before starting engine. 2.1 Turn fuel cock lever to “ON”. 2.2 Turn chock lever to “CLOSE”. 2.3 Turn engine switch to “ON”. 2.4、Pull slowly on recoil starter until engaged, then pull it briskly. 2.5 Return chock lever.
  • Page 8: Stopping The Engine

    4. STOPPING THE ENGINE 4.1 Before stopping turn off electric apparatus. 4.2 Turn engine switch to “STOP”. 4.3Turn fuel cock lever to “OFF”. 5 CONNECTION 5.1 Wind lead 2 or 3 turns around handle. 5.2 Start engine. 5.3 Plug into Ac socket. SAFETY DEVICES Press to rest AC protector.
  • Page 9: Periodic Maintenance

    4. PERIODIC MAINTENANCE Every 50hrs Every 150rs Items Remarks Every month Every 3 months Spark plug Remove carbon Adjust gap ※ Replace if necessary Air filter Clean ※ Replace if necessary Fuel filter Clean ※ Replace if necessary Decabonigation Clean ※...
  • Page 10: Air Filter

    AIR FILTER 1. Air filter 2. Wash in solvent 3. Motor oil (SEA #20) 4. Squeegee out . Never run engine without element. FUEL FILTER 1. Clean in solvent 2. Wipe off 3. Insert - 6 -...
  • Page 11: Troubleshooting

    5. APPLICATION PAGE Apparatus AAP 1000 Power factor 50Hz 60Hz 50Hz 0.7~0.8 60Hz 50Hz 0.7~0.95 60Hz 6. TROUBLESHOOTING ENGINE WON’T START 1. Check fuel. Fuel cock to “ON” . 2. Engine switch to “ON”. 3. Check spark plug. 4. If engine still won’t start, check following.
  • Page 12: Specifications

    7. SPECIFICATIONS AC Output Unit AAP 1000 Rated Voltage Frequency DC Voltage Rated Output Max Power AAP 1000 Engine Operation hours 50Hz 60Hz - 8 -...
  • Page 15: Declaration Of Conformity

    şartlara uygun olduğunu beyan ederiz. On behalf of AKSA Jeneratör San. A.Ş, We declare that above information in relation on the supply/manufacture of this in product is in conformity with the below stated standarts, EC directives and provisions of them.
  • Page 16 AKSA JENERATÖR YETKİLİ SERVİS NOKTALARI İSTANBUL AVRUPA YAKASI AVCILAR MUSTAFA KEMAL PAŞA MAH. YILDIRIM BEYAZIT CAD. DEMET SOK. NO:132 AVCILAR / İSTANBUL T: 0 212 428 66 66 PBX F: 0 212 423 22 22 BAĞCILAR ORTAK BÖLGE ( GÖKSU ) FATİH, ZEYTİNBURNU, GAZİOSMANPAŞA, EYÜP MERKEZ MAH.
  • Page 20 Genel Müdürlük / Head office Aksa Servis ve Yedek Parça / Aksa Service & Spare Parts Aksa Kiralama / Aksa Rental Fabrikalar / Factories...