When 2 Units Are Installed In 1 Room - Daikin CTXS07LVJU Service Manual

Hide thumbs Also See for CTXS07LVJU:
Table of Contents

Advertisement

SiUS121602E

4.2.3 When 2 Units are Installed in 1 Room

Outline
When 2 indoor units are installed in 1 room, 1 of the 2 indoor units and the corresponding wireless
remote controller can be set for different address.
Both the indoor unit PCB and the wireless remote controller need alteration.
The method of address setting varies depending on the type of indoor unit and the series of wired
remote controller. Refer to the following pages for the appropriate indoor unit and wireless remote
controller.
CTXS, FTXS
(1) Remove the front grille.
(2) Remove the electrical box.
Series
(3) Remove the shield plate of the electrical box.
(4) Cut the address setting jumper JA on the PCB.
CTXS07LVJU, FTXS09/12LVJU
Caution
Replace the PCB if you accidentally cut a wrong jumper.
Jumpers are necessary for electronic circuit. Improper operation may occur if you cut any of them.
CDXS, FDXS
Series
Caution
Replace the PCB if you accidentally cut a wrong jumper.
Jumpers are necessary for electronic circuit. Improper operation may occur if you cut any of them.
Trial Operation and Field Settings
JB
JA
JC
Cut the jumper JA on PCB.
ADDRESS : JA
JA
EXIST
1
CUT
2
FTXS15/18LVJU
JB
JA
JC
(R17375)
1
2
3
(R22010)
Field Settings
(R9665)
187

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents