JVC PD-50X795 Service Manual page 40

Pdp color television
Hide thumbs Also See for PD-50X795:
Table of Contents

Advertisement

< Page 2 of screen (DISPLAY UNIT) >
Detection item
Display
Fan lock
FAN
[PD-50X795]
Abnormal of operation
ALM
of PDP (PANEL)
Abnormal rise of
TMP
temperature in PDP
(PANEL)
Abnormal rise of
ATP
temperature in AUDIO
PWB
Short circuit detection
ASH
of AUDIO PWB
Panel communication
PNL
Panel memory
MEM
Temp. sensor
TMP
operation
Audio control
AIO
5.1.7 METHOD OF DISPLAY WHEN A RASTER IS NOT OUTPUT
In the state where a raster is not output by breakdown of the set, an error is displayed by blink of the POWER LED.
Type of error
Low bias line short protection
Fan lock [Receiver unit]
ATSC digital tuner error
Fan lock [Display unit]
Abnormal of operation of PDP (PANEL)
Abnormal rise of temperature in PDP (PANEL)
< Explanation of operation >
If error is detected, the power is turned off.
Shortly after a power is turned off, POWER LED will be blinked.
Power cannot be turned on until the power cord takes out and inserts, after a power is turned off.
1-40 (No.YA100)
Detection content
Confirm the operation of the cooling
fan.
IC807 [DISPLAY INTERFACE PWB]
Confirm the operation of the panel
protection.
[PDP UNIT]
It detects whether the temperature in a
display unit is normal.
IC8101 [TEMP. SENSOR PWB]
Not used.
Not used.
It confirm whether panel
communication is normal.
[PDP UNIT]
Confirmation of reply of ACK signal
2
which uses I
C communication.
IC805 [DISPLAY INTERFACE PWB]
Same as above.
IC8101 [TEMP. SENSOR PWB]
Same as above.
IC6521 [AUDIO PWB]
Display
LOB
Low luminance blue Flash 1.0 second / Low luminance blue Out 1.0 seconds
FAN
Low luminance blue Flash 0.1 second / Low luminance blue Out 0.1 seconds
---
Low luminance blue Flash 2.0 second / Low luminance blue Out 2.0 seconds
FAN
High luminance blue Flash 0.1 second / High luminance blue Out 0.1 seconds
ALM
High luminance blue Flash 1.0 second / High luminance blue Out 1.0 seconds
TMP
High luminance blue Flash 2.0 second / High luminance blue Out 2.0 seconds
Diagnosis
signal
(line)
FAN_LOCK Detection starts 8 seconds after the power is
turned on.
Detection is performed every 16ms.
If errors continues between 300ms the power
is turned off.
SDA
Detection starts 8 seconds after the power is
turned on.
Detection is performed every 16ms.
If errors continues between 300ms the power
is turned off.
SDA
Detection starts 8 seconds after the power is
turned on.
Detection is performed every 0.5 seconds.
If a temperature rises beyond the temperature
of 71ºC for detection of error over the
predetermined 120 times the power is turned
off.
---
Not used.
---
Not used.
SDA
If it checks whenever I
performed and no reply of ACK signal an error
will be counted.
SDA
Same as above.
SDA
Same as above.
SDA
Same as above.
POWER LED flash cycle
Detection timing
2
C communication is
Unit
RECEIVER UNIT
RECEIVER UNIT
RECEIVER UNIT
DISPLAY UNIT
[PD-50X795]
DISPLAY UNIT
DISPLAY UNIT

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pd-42x795

Table of Contents