5.1.6 DETAILS
Self check is performed for the following items:
< Page 1 of screen (RECEIVER UNIT) >
Detection item
Display
Low bias line short
LOB
protection
Fan lock
FAN
Presence of sync
SYNC Confirmation of presence of video
signal
AC power input
TIM
Main CPU
MSM
communication
Digital tuner
DIG
Main memory
MEM
AV select switch
AVSW Same as above.
3 dimensions YC
YC
separator
Multi sound process
AIO
RF tuner
TUN
Ghost reduction
GCR
DIST process
IP
RGB process
RGB
DVI (Digital
DVI
communication)
Digital input
HDMI
Detection content
Confirm the operation of the low bais
(2.5V / 3.3V / 5V / 9V) protection circuit.
Q9822 [REGULATOR PWB]
Confirm the operation of the cooling fan.
IC711 [ANALOG SIGNAL PWB]
sync signal.
M : Main sync signal
S : Sub sync signal
HD : Component sync signal
IC201 [ANALOG SIGNAL PWB]
Not used.
Confirmation of ACK (response)
signal which uses sync communications
with Chassis CPU.
IC7601 [DIGITAL SIGNAL PWB]
Not used.
Same as above
IC7602 [DIGITAL SIGNAL PWB]
IC301, IC501 [ANALOG SIGNAL PWB]
Same as above.
IC1001 [DIGITAL SIGNAL PWB]
Same as above.
IC3101 [RECEIVER PWB]
Same as above.
TU3001 [RECEIVER PWB]
Not used.
Confirmation of reply of ACK signal
2
which uses I
C communication.
IC3001 [DIGITAL SIGNAL PWB]
Same as above.
IC4001 [DIGITAL SIGNAL PWB]
Same as above.
IC6101 [DIGITAL SIGNAL PWB]
Same as above.
IC8001 [DIGITAL SIGNAL PWB]
Diagnosis
signal
Detection timing
(line)
LB_PRO
Detection starts 3 seconds after the power is
turned on.
If error continues between 400ms the power is
turned off.
FAN_LOCK Detection starts 3 seconds after the power is
turned on.
If error continues between 250ms the power is
turned off.
SDA
Confirmation of presence of sync signal in
video signal.
---
WAKE
If it checks whenever sync communication with
sub (chassis) CPU performed and no reply of
ACK signal an error will be counted.
---
SDA
If it checks whenever I
performed and no reply of ACK signal an error
will be counted.
SDA
Same as above.
SDA
Same as above.
SDA
Same as above.
SDA
Same as above.
---
SDA
If it checks whenever I
performed and no reply of ACK signal an error
will be counted.
SDA
Same as above.
SDA
Same as above.
SDA
Same as above.
---
---
2
C communication is
---
2
C communication is